Hello,
After upgrading to 12.2(58)SE1 on a ME3400 seems like all the input CIR with
BC configured like this stopped working:
policy-map CIR_4096
class class-default
police cir 4096000 bc 256000
conform-action transmit
exceed-action drop
When trying to apply the following to an
Anyone run into CSCti84025 on a C6K, VS-S720-3C, 12.2(33)SXI3?
VRFs hardware re-mapping causing MLS/CEF inconsistencies
Symptom:
On a Catalyst 6500 series switches, connectivity in VRFs may be affected after
a large reconvergence. Another symptom of the issue is the presence of invalid
mls
Looks like you are hitting a new defect that starts in your code: CSCtq24633
It's not yet fixed so configuring no be for the time being would be the
best available workaround until the fix is integrated in the next release.
Regards,
John
On 5/16/11 6:31 AM, Pavel Skovajsa wrote:
Hello,
All,
Noticed an unexpected result today when testing VSS failover. Our
setup has dual sups in each chassis, with a supervisor port of each chassis
connecting to the matching supervisor port on the other chassis, i.e. 1/5/4
connects to 2/5/4, and 1/6/4 connects to 2/6/4. Today when