Any one using IP-SLA on a 7600 running 12.2(33)SRE3? I have a customer wanting
to use it for a backup circuit. Have not configured it before...
Thanks,
Bill
Bill Buhlman
Network Engineer
Contra Costa County Office of Education
77 Santa Barbara Road
Pleasant Hill, CA 94523
925-942-5362
l do this?
Cisco of course wants to sell me an ASR9K but I am not apposed to staying with
the 7600 if it can hang with a few new or used parts
Thanks in advance!
-Bill
Bill Buhlman
Network Engineer
Contra Costa County Office of Education
77 Santa Barbara Road
Pleasant Hill, CA 9
I have to convert to AFI for IPv6, will my IPv4 BGP session drop when I do the
conversion " bgp upgrade-cli" ?
Bill
___
cisco-nsp mailing list cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck
Anyone know of an online ipv6 tool that will allow you to specify # of bits
when calculating? Trying to subnet a /32 into /48's.
Thanks,
Bill
___
cisco-nsp mailing list cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco
Working on a small LAN with a 2651 router as its gateway. Periodically
workstations will loose connectivity to the gateway at fa0/0. All workstations
are WinXP. Repairing the network connection reinstates the connectivity. Would
the group please give suggestions on the cause? I don't see anythin
MLPPP
working config below. Do the same thing on the remote router ie:create
multilink interface with IP address and add DS1 interfaces to multilink group
interface Multilink1
description Orinda bundle DS3 channels 11,18,12
ip address xxx.xxx.x.177 255.255.255.252
ip flow ingress
ppp multili
Example of lightly loaded 7609 running at 240v redundant with 3000watt supplies
and sup720-3b. No POE.
edge#sh power
system power redundancy mode = redundant
system power total = 2771.16 Watts (65.98 Amps @ 42V)
system power used = 1636.74 Watts (38.97 Amps @ 42V)
system power available
Hi,
I'm running 12.2(33)SRA6 on a 7609-Sup720-3b. Its been up for about a year aand
a half. When
I first deployed it, I was able to login with ssh first try with Putty. About 4
months later
after I put in username and password, the session hangs until I get "protocol
error:
expected type 50 g
We have always used TIA/EIA standards documents for data center, MDF,IDF.
TIA-568, TIA-569, TIA-570, TIA-606, TIA-942. Available from
http://global.ihs.com/
Bill
--- On Thu, 4/23/09, Renelson Panosky wrote:
From: Renelson Panosky
Subject: [c-nsp] Cisco Standard closet
To: cisco-nsp@puck.ne
Does anyone have a document they follow when doing a network survey? I'd rather
not create one from scratch. Please send replies to billbuhl...@yahoo.com
Thanks,
Bill
___
cisco-nsp mailing list cisco-nsp@puck.nether.net
https://puck.nether.ne
Hi,
We've been adding clients onto AT&T's "OPTEMAN" Ethernet service running
12.2.33 SRB and looking at the physical interface stats there are quite a few
giants:
5 minute output rate 10862 bits/sec, 12609 packets/sec
11534799216 packets input, 2729015090593 bytes, 0 no buffer
Hi,
I have a question about my local router ID in BGP. We connect to our ISP
through eBGP and our local router ID has been a private address (192.168.x.x)
for years configured on VLAN 1 of our 7609. I was thinking about changing it
because most everyone I see has a public IP for the local ID.
Hi All,
We've installed a new 7609 recently (up 3 weeks) and run BGP to connect to
our upstream provider. We are announcing two prefixes, a /16 and /24. Since the
install I've noticed connectivity to the ISP has gone down for a few minutes
about 10 times, never during business hours. A couple
There is also a lot of information in the EIA/TIA standards documents about
server and equipment rooms. You can get them on CD from Global Engineering
Documents in Colorado, USA. phone 800-624-3974
Bill
[EMAIL PROTECTED] wrote:
Hi,
We had a 7500 with two CHDS3 and one ATM/OC3 that had been very stable for
years, then 3 years ago moved to 7606 with Flexwan module using the same PA's
from the 7500 and had nothing but trouble with the Flexwan's. Probably RMA'd 5
of them in 3 years. We are now moving to 7609 with SIP/SPA
Matti,
I also have seen this error log:
*Apr 14 04:29:45 PDT: %PM_SCP-SP-2-LCP_FW_ERR_INFORM: Module 4 is
experiencing the following error:
Port 0 BCast Suppress Value Changed: exp: 0xf actual:0x0
We have a 7606/sup 2, 12.1(27b)E1 with the same X6408A module in slot 4. We
do have br