On 05/18/2011 12:31 AM, Church, Charles wrote:
Phil,
The VSS is the 'bonding' of 2 6500 chassis into one, with one CLI
controlling both chassis. Kind of like a 3750 stack. Up until I think
;o)
I do know what VSS is and how it works; I meant I wasn't familiar with
the specific
Anyone? Otherwise gonna ask TAC, just want to verify my thoughts.
Thanks,
Chuck
-Original Message-
From: cisco-nsp-boun...@puck.nether.net
[mailto:cisco-nsp-boun...@puck.nether.net] On Behalf Of Church, Charles
Sent: Monday, May 16, 2011 6:07 PM
To: nsp-cisco
Subject: [c-nsp] 6500 VSS
On 17/05/11 16:31, Church, Charles wrote:
Anyone? Otherwise gonna ask TAC, just want to verify my thoughts.
I know nothing much about VSS, but I see a couple of confusing aspects
in your email; you refer to instant failover (which is SSO), RPR+ and eFSU.
Can you elaborate on the exact
Subject: Re: [c-nsp] 6500 VSS question
Anyone? Otherwise gonna ask TAC, just want to verify my thoughts.
Thanks,
Chuck
-Original Message-
From: cisco-nsp-boun...@puck.nether.net
[mailto:cisco-nsp-boun...@puck.nether.net] On Behalf Of Church, Charles
Sent: Monday, May 16, 2011 6:07 PM
: Re: [c-nsp] 6500 VSS question
Is your redundancy mode set to RPR? I think what you are doing only
works
if the mode is set to SSO...
-Original Message-
From: cisco-nsp-boun...@puck.nether.net
[mailto:cisco-nsp-boun...@puck.nether.net] On Behalf Of Church, Charles
Sent: Tuesday, May 17
: [c-nsp] 6500 VSS question
On 17/05/11 16:31, Church, Charles wrote:
Anyone? Otherwise gonna ask TAC, just want to verify my thoughts.
I know nothing much about VSS, but I see a couple of confusing aspects
in your email; you refer to instant failover (which is SSO), RPR+ and eFSU.
Can you
:44 PM
To: Murphy, William; Church, Charles; nsp-cisco
Subject: RE: [c-nsp] 6500 VSS question
I haven't looked TOO in-depth on this yet, but with VSS and 4
supervisors, do all 4 come up in SSO mode, or do the first 2 come up in
SSO, and the other two come up in RPR+ mode?
4 Supervisor VSS is still
All,
Noticed an unexpected result today when testing VSS failover. Our
setup has dual sups in each chassis, with a supervisor port of each chassis
connecting to the matching supervisor port on the other chassis, i.e. 1/5/4
connects to 2/5/4, and 1/6/4 connects to 2/6/4. Today when