Hi Rodney,
Thanks for the response...
was fixed in 12.0(32)SY3.
Is this seen on 32SY3?
Yes, I saw it come up on one of our GSRs running 12.0(32)SY3 several
times but have not noticed it since (not logging to syslog on these
routers so I can't go back very far to make sure).
Here's show
Aaron,
It's a bug.
CSCse04192
Internally found cosmetic defect: Resolved (R)
NRT:lreuse:Can't write label reuse data to standby RP pdata file
was fixed in 12.0(32)SY3.
Is this seen on 32SY3?
On Thu, Aug 23, 2007 at 09:19:53AM -0400, Aaron Daubman wrote:
Greetings,
I just saw these two
Greetings,
I just saw these two messages logged on a GSR running 12.0(32)SY3 for
the first time this morning (MPLS is not currently in use):
Aug 22 07:58:13.871 EDT: %MPLS_LABEL_REUSE-3-FAILURE: Can't write
label reuse data to pdata file
-Traceback= 20599C 205AA4 ED5BB8 ED77A0 ED7890 ED7E3C