Author: burn
Date: Tue Oct  6 17:49:32 2015
New Revision: 1707102

URL: http://svn.apache.org/viewvc?rev=1707102&view=rev
Log:
Merge in latest UIMA-4598 fixes to perfomance metrics

Modified:
    
uima/sandbox/uima-ducc/branches/uima-ducc-2.0.1/uima-ducc-user/src/main/java/org/apache/uima/ducc/user/jp/UimaProcessContainer.java
   (contents, props changed)

Modified: 
uima/sandbox/uima-ducc/branches/uima-ducc-2.0.1/uima-ducc-user/src/main/java/org/apache/uima/ducc/user/jp/UimaProcessContainer.java
URL: 
http://svn.apache.org/viewvc/uima/sandbox/uima-ducc/branches/uima-ducc-2.0.1/uima-ducc-user/src/main/java/org/apache/uima/ducc/user/jp/UimaProcessContainer.java?rev=1707102&r1=1707101&r2=1707102&view=diff
==============================================================================
--- 
uima/sandbox/uima-ducc/branches/uima-ducc-2.0.1/uima-ducc-user/src/main/java/org/apache/uima/ducc/user/jp/UimaProcessContainer.java
 (original)
+++ 
uima/sandbox/uima-ducc/branches/uima-ducc-2.0.1/uima-ducc-user/src/main/java/org/apache/uima/ducc/user/jp/UimaProcessContainer.java
 Tue Oct  6 17:49:32 2015
@@ -284,7 +284,7 @@ public class UimaProcessContainer extend
        private void getLeafManagementObjects(AnalysisEngineManagement aem,
                        List<AnalysisEnginePerformanceMetrics> result,
                        String uimaFullyQualifiedAEContext) {
-
+//             System.out.println("----------- 1 getLeafManagementObjects() - 
Unique Name:"+aem.getUniqueMBeanName()+" 
UniqueContext:"+uimaFullyQualifiedAEContext);
                if (aem.getComponents().isEmpty()) {
                        // skip Flow Controller
                        if (!aem.getName().equals("Fixed Flow Controller")) {
@@ -297,36 +297,20 @@ public class UimaProcessContainer extend
                                // Components,p2=ThirdLevelAggregateCM
                                // Components,name=Multiplier1
                                if (aem.getUniqueMBeanName().indexOf("p0=") > 
-1) {
-                                       uimaFullyQualifiedAEContext = "";
-/*
-                                       // check id the parent aggregate has 
been scaled up by
-                                       // looking at the last char in its 
name. If it is a number
-                                       // strip it from the name
-                                       if 
(Character.isDigit(uimaFullyQualifiedAEContext
-                                                       
.charAt(uimaFullyQualifiedAEContext.length() - 1))
-                                                       && 
uimaFullyQualifiedAEContext.lastIndexOf(" ") > -1) {
-                                               String indx = 
uimaFullyQualifiedAEContext
-                                                               
.substring(uimaFullyQualifiedAEContext
-                                                                               
.lastIndexOf(" "));
-                                               if (indx != null) {
-                                                       int value = -1;
-                                                       try {
-                                                               value = 
Integer.parseInt(indx.trim());
-                                                               // Prepend "X 
Components" to the unique name
-                                                               // with X 
stripped.
-                                                               
uimaFullyQualifiedAEContext = value
-                                                                               
+ " Components "
-                                                                               
+ uimaFullyQualifiedAEContext
-                                                                               
                .substring(
-                                                                               
                                0,
-                                                                               
                                uimaFullyQualifiedAEContext
-                                                                               
                                                .lastIndexOf(" "));
-                                                       } catch 
(NumberFormatException ex) {
+                                   int p1indx = 
aem.getUniqueMBeanName().indexOf("p1=");
+                                   if ( p1indx > -1 ) {
+                                       String tmp = 
aem.getUniqueMBeanName().substring(p1indx);
+                                       String[] parts = tmp.split(",");
+                                       for( String part : parts ) {
+                                               if ( part.startsWith("name=") ) 
{
+                                                       
uimaFullyQualifiedAEContext += "/"+part.substring(5);
+                                                       break;
+                                               }
+                                       }
+                                   } else {
+                                               uimaFullyQualifiedAEContext = 
"";
+                                   }
 
-                                                       }
-                                               }
-                                       }
-                                       */
                                }
                                result.add(deepCopyMetrics(aem, 
uimaFullyQualifiedAEContext));
                        }
@@ -437,19 +421,26 @@ public class UimaProcessContainer extend
                        List<AnalysisEnginePerformanceMetrics> 
afterAnalysisManagementObjects,
                        List<AnalysisEnginePerformanceMetrics> 
beforeAnalysisManagementObjects)
                        throws Exception {
-               // Create a List to hold per CAS analysisTime and total number 
of CASes
-               // processed
-               // by each AE. This list will be serialized and sent to the 
client
+               // Create a List to hold per CAS analysisTime and total number 
of CASes processed by each AE. 
+               // This list will be serialized and sent to the client
                List<AnalysisEnginePerformanceMetrics> performanceList = new 
ArrayList<AnalysisEnginePerformanceMetrics>();
-               // Diff the before process() performance metrics with post 
process
-               // performance
-               // metrics
+               // Diff the before process() performance metrics with post 
process performance metrics
                for (AnalysisEnginePerformanceMetrics after : 
afterAnalysisManagementObjects) {
                        for (AnalysisEnginePerformanceMetrics before : 
beforeAnalysisManagementObjects) {
+                               String uniqueName = after.getUniqueName();
                                if 
(before.getUniqueName().equals(after.getUniqueName())) {
+                                       /*
+                                       int p1 = 
after.getUniqueName().indexOf("DUCC.Job");
+                                       if ( p1 >-1 ) {
+                                               int p2 = 
after.getUniqueName().indexOf("/",p1);
+                                               if ( p2 >-1 ) {
+                                                       uniqueName = 
after.getUniqueName().substring(p2);
+                                               }
+                                       }
+                                       */
 
                                        AnalysisEnginePerformanceMetrics 
metrics = new AnalysisEnginePerformanceMetrics(
-                                                       after.getName(), 
after.getUniqueName(),
+                                                       after.getName(), 
uniqueName,
                                                        after.getAnalysisTime() 
- before.getAnalysisTime(),
                                                        
after.getNumProcessed());
                                        // 
System.out.println("********************"+metrics.getUniqueName());

Propchange: 
uima/sandbox/uima-ducc/branches/uima-ducc-2.0.1/uima-ducc-user/src/main/java/org/apache/uima/ducc/user/jp/UimaProcessContainer.java
------------------------------------------------------------------------------
--- svn:mergeinfo (added)
+++ svn:mergeinfo Tue Oct  6 17:49:32 2015
@@ -0,0 +1 @@
+/uima/sandbox/uima-ducc/trunk/uima-ducc-user/src/main/java/org/apache/uima/ducc/user/jp/UimaProcessContainer.java:1693975-1706485,1707056