+1
> -Original Message-
> From: Mailing list for users of COOT Crystallographic Software
> [mailto:COOT@JISCMAIL.AC.UK] On Behalf Of Dirk Kostrewa
> Sent: Thursday, April 14, 2011 5:37 AM
> To: COOT@JISCMAIL.AC.UK
> Subject: Re: [COOT] low res real-space refinement
>
> Another idea, that
Hi Jim,
two ways I can think of to solve this.
1) from the driver side, see if the MAC comes with 'nvidia-settings'. If it
does under 'OpenGL' settings should be an entry for 'Exchange Stereo Eyes'.
2) from within coot one can manipulate the stereo angle:
(set-hardware-stereo-angle-factor f) Tr
Chris,
this is a hardware problem. The older NVIDIA cards together with the
stereographics emitter used to do that. The only fix I know is to upgrade the
card to a later model. I have not seen this with a FX3800 using 120Hz LCDs and
NVIDIA 3D vision.
HTH
Carsten
> -Original Messa
Mirek,
coot's merging algorithm is a bit over-cautious in these cases. Try using
"Calculate->Change Chain ID" and define the residue ranges for the merge, that
should help.
HTH
Carsten
> -Original Message-
> From: Mailing list for users of COOT Crystallographic Software
> [m
MAIL.AC.UK
> Subject: Re: [COOT] Failure to mount /home/emsley delays coot startup
>
> On Wed, Jun 23, 2010 at 06:03:22PM +0100, Paul Emsley wrote:
> > On 23/06/10 13:26, Schubert, Carsten [PRDUS] wrote:
> > >Is there any way to get rid of these references in the pre-compil
Hi,
I wonder if anyone has a solution to this problem. We are starting to
run coot (0.6.2 pre) on SuSe Enterprise 10.x edition machines. The load
times per session are approx 2 minutes, before coot is up and running.
Loading with the older RedHat EL 4 machines is almost instantaneous from
the same
Hi,
is there a way to toggle the use of Hydrogens in the mutate and add
terminal residue commands? Currently coot (2486) does not seem to allow
building of Hydrogens upon changing or adding residues.
If that is not currently possible, what are the plans to include that
functionality, would be nic
Thanks for your comments Paul. I see what we can do about the updates...
Cheers,
Carsten
> -Original Message-
> From: Paul Emsley [mailto:paul.ems...@bioch.ox.ac.uk]
> Sent: Tuesday, September 29, 2009 11:04 PM
> To: Schubert, Carsten [PRDUS]; coot@jiscmail.ac.uk
&
Hi,
On redhat El4 with coot 0.6-2283 (Centos-python-gtk2) the rot-trans
button in the toolbar does not show up. Toggling the button in the
preferences produces the following warning:
*** (coot-real 4220: WARNING **: Widget not found:
model_toolbar_rot_trans_toolbutton
The button is however prese
Hi Paul,
would it be possible to have a feature in which Hydrogens present in the
model are ignored, when checking for questionable waters in the
Check/Delete Waters functionality? Turns out that the default close
contact of 2.3A is too inclusive and leads to a lot of questionable or
worse deleted
Probably just the latter (guess on my part) If you need tighter geometry
you can decrease the matrix weight under Extensions->Refine->Set Matrix
for the real space refinement. The default (60, in 0.6pre) is suitable
for good density, set it lower for marginal density. That way you still
get good ge
nix for this purpose.
Schubert, Carsten [PRDUS] wrote:
> Hi,
> Sorry for the crosspost, but I am not sure were the problem is located:
> I noticed that the xplor maps generated by phenix seem to be on a different
> scale than the maps generated from the map-coefficients from the same
Hi,
Sorry for the crosspost, but I am not sure were the problem is located:
I noticed that the xplor maps generated by phenix seem to be on a different
scale than the maps generated from the map-coefficients from the same
refinement run when the maps-coeffs are read into coot. Usually I only rea
ubject: Re: [COOT] Stereo projection with Coot
Schubert, Carsten [PRDUS] wrote:
> Yep it does. On linux there may be issues, because the drivers may or may not
> support swap-eyes. The problem is that the images are out of sync with the
> glasses, or to be more precise, the left image is disp
Yep it does. On linux there may be issues, because the drivers may or may not
support swap-eyes. The problem is that the images are out of sync with the
glasses, or to be more precise, the left image is displayed when the right
shutter on the glasses is open. That was the case with the version w
Would it be possible to enhance the "Change Chain ID.." function to allow for
insertion of residues into an existing chain if the given resid range is not
occupied?
For instance I have a single atom already present in the loaded pdb file with
chain B and resid 1, otherwise chain B is empty. Afte
Hi Paul,
could you please comment on the precedence of the default settings in either
".coot-preferences/coot-preferences.scm" or its python equivalent. The comments
in the file state that the user should feel free to edit the values, but not
add/delete entries. This could potentially lead to a
Hi,
I noticed a couple of issues with 0.5.1-pre-1474.
- The following settings for dialog positions seem to be no longer honored by
coot,
I tried both the python and scheme commands with the same lack of effect:
set_model_fit_refine_dialog_position()
set_delete_dialog_position()
set_rot
Nat, is probably right. I did not see a "Module" section in your xorg.conf
file, which is required.
Attached are 2 examples of xorg.conf. One for single screen CRT, the other for
a dual head FX Quadro card, which uses 2 monitors. Use them as templates to
adapt to your configuration.
HTH
Try to change the SG to H3. Worked for me
Carsten
> -Original Message-
> From: Mailing list for users of COOT Crystallographic Software
> [mailto:[EMAIL PROTECTED] Behalf Of Watier Yves
> Sent: Friday, July 11, 2008 10:45 AM
> To: COOT@JISCMAIL.AC.UK
> Subject: [COOT] Problem displaying R
Joe
coot currently does not handle PDB V3 hydrogens. You need to tell reduce to
write out old style hydrogens. This should take of this problem.
Carsten
-Original Message-
From: Mailing list for users of COOT Crystallographic Software [mailto:[EMAIL
PROTECTED] Behalf Of Joe Batchelor
Andreas,
try (set-graphics-window-size x y) in the command input. Replace x, y with the
desired dimensions. Works in the .coot file, no reason why not interactively
(FLW).
Cheers,
Carsten
> -Original Message-
> From: Mailing list for users of COOT Crystallographic Software
> [
22 matches