Il giorno Mon, 20 Jan 2020 14:52:55 -0800
jys ha scritto:
> On Mon, Jan 20, 2020, at 09:03, ilario.quinson@e.email wrote:
>
> > Hi, everybody. DT 3 on MacOS 10.13 exports only one photo to JPEG
> > at a time even if I select more. Does that happen to you too?
> > Thanks
>
> Are you maybe
On Mon, Jan 20, 2020, at 09:03, ilario.quinson@e.email wrote:
> Hi, everybody. DT 3 on MacOS 10.13 exports only one photo to JPEG at a
> time even if I select more. Does that happen to you too? Thanks
Are you maybe hovering over a thumbnail when typing Ctrl+E? The lighttable has
a
> > - are both DT and Gweenview using the correct color calibration with the
> > same monitor profiles?
> I don't use color calibration, I don't know how to do. My configuration is by
> default ... normally. Where can I check it ?
If the color profile is properly setup on the OS, Gwenview will
> > Do you use haze removal?
> Yes I did.
>
> > Will the problem still persist if you deactivate it?
> >
> No it didn't. I have just try to deactivate it and the problem have
> disappear.
>
Then you were probably hit by
https://github.com/darktable-org/darktable/issues/4092
>
Le 20/01/2020 à 11:59, thokster a écrit :
Am 18.01.20 um 23:59 schrieb Marc Mascré:
Hello every one.
Sometimes, after finishing the development of my photo, I don't have
the same rendering in darktable and after the export.
Do you use haze removal?
Yes I did.
Will the problem still
dt-l...@stefan-klinger.de schrieb am 19.01.20 um 22:55:
Stefan Klinger (2020-Jan-19, excerpt):
or there might be a sign error in “filmic” (that nobody has
noticed?!).
Now this "change" (I'm not claiming it to be a "fix"), would give me
bahaviour I personally would expect: In
GianLuca Sarto schrieb am 20.01.20 um 14:03:
On 20/01/20 12:01, Bernhard wrote:
GianLuca Sarto schrieb am 20.01.20 um 09:54:
Hello All,
DNG produced with a Nikon LS5000 scanner show a skull instead of the
image.
With DT 2.6 everything was in place.
what software is used for the scanner
Hi, everybody. DT 3 on MacOS 10.13 exports only one photo to JPEG at a time
even if I select more. Does that happen to you too? Thanks
-- Inviato da /e/ Mail.
darktable user mailing list
to unsubscribe send a mail to
GianLuca Sarto schrieb am 20.01.20 um 09:54:
Hello All,
DNG produced with a Nikon LS5000 scanner show a skull instead of the image.
With DT 2.6 everything was in place.
what software is used for the scanner to produce the DNG?
--
regards
Bernhard
https://www.bilddateien.de
Am 18.01.20 um 23:59 schrieb Marc Mascré:
Hello every one.
Sometimes, after finishing the development of my photo, I don't have
the same rendering in darktable and after the export.
Do you use haze removal?
Will the problem still persist if you deactivate it?
I don't understand, did I
Hi,
You can find here the tiff file with his xmp and the export I get in jpg :
http://documents.mascre.fr/darktable/
For the moment I only have this one. If an other appear I will share you.
Thanks
Le 20/01/2020 à 08:12, KOVÁCS István a écrit :
Hi,
I have to precise the problem
I'm running the official install of dt 3.0 for Mac on a 2017 Retina 4K
iMac under MacOS 10.14.6 (Mojave). I've installed the Roboto font set,
and I'm using the darktable-elegant-grey theme. However, the interface
is not using the Roboto font.
(I've rebooted the Mac since installing Roboto, but dt
Hello All,
DNG produced with a Nikon LS5000 scanner show a skull instead of the image.
With DT 2.6 everything was in place.
-Gian
darktable user mailing list
to unsubscribe send a mail to
13 matches
Mail list logo