Hello Istvan, Colin, Patrick,
>From reading the user blog and a few tests I found that the preferences >(except presets and shortcuts) are being stored in a file named ‘darktablerc’. > So right before after upgrading to 3.2.1 one needs to rename ‘darktablerc’. Under Windows this file sits in ‘C:\Users\<username>\AppData\Local\darktable’. For other systems see trail herebelow. Please don’t hesitate to further comment if this advice needs to be complemented. Marc. Van: marc.ca...@gmail.com <marc.ca...@gmail.com> Verzonden: vrijdag 14 augustus 2020 12:45 Aan: 'Colin Adams' <colinpaulad...@gmail.com>; 'Darktable Mailing List' <darktable-user@lists.darktable.org> CC: 'KOVÁCS István' <k...@kovacs-telekes.org> Onderwerp: RE: [darktable-user] base curve always applied even with an empty preference tick box Colin, Istvan, Got it solved by implementing Istvan’s solution (*) by combining it with Colin’s solution (°). Without Colin’s solution the base curve continued to appear. I have now the filmic and exposure modules appearing as a result of the scene-referred setting (*). Thanks all, Marc. (*) Istvan’s solution In 3.2.1, there are two settings that are related to the base curve: - processing -> auto-apply pixel workflow defaults: if set to 'display-referred', the base curve will be applied; if set to 'scene-referred', filmic will be applied; if set to none, neither will be applied - processing -> auto-apply per camera basecurve presets: if checked, a camera-specific basecurve (such as Nikon D7000) will be applied instead of a more generic one (e.g. Nikon) If you want to skip the base curve, set your workflow defaults to 'scene-referred' or 'none' (and restart darktable). (°) Colin’s solution (see also Colin’s mail here under) Did not find immediately the meant “.config/darktable folder” on Windows, so I unistalled darktable and reinstalled. Will research this further a next release upgrade. Van: Colin Adams <colinpaulad...@gmail.com <mailto:colinpaulad...@gmail.com> > Verzonden: vrijdag 14 augustus 2020 6:49 Aan: marc.ca...@gmail.com <mailto:marc.ca...@gmail.com> Onderwerp: Re: [darktable-user] base curve always applied even with an empty preference tick box I had the same problem. I renamed my .config/darktable folder in order to force generation of a new one. The problem then disappeared. On Thu, 13 Aug 2020 at 21:42, < <mailto:marc.ca...@gmail.com> marc.ca...@gmail.com> wrote: Hello, I am still learning darktable (new since July) and upgraded from 3.0.2 to 3.2.1 on Windows 10. In darktable 3.0.2 I had the “auto-apply of the base curve” switched off (empty tick box) in the preferences. Now in 3.2.1 it does always apply the base curve whether ticked on or not. I guess this is a bug. Is this known ? And if not where do I report it ? Also, other darktable 3.2.1 users may check it on their system/platform. Marc. ____________________________________________________________________________ darktable user mailing list to unsubscribe send a mail to <mailto:darktable-user%2bunsubscr...@lists.darktable.org> darktable-user+unsubscr...@lists.darktable.org ____________________________________________________________________________ darktable user mailing list to unsubscribe send a mail to darktable-user+unsubscr...@lists.darktable.org