Bug#1009231: Write errors since upgrade to 9.6.7-4

2022-04-15 Thread Sven Hartge
On 15.04.22 13:29, Klaus Ethgen wrote: I also have a nagios bacula monitor running every 5 minutes. (/usr/lib/nagios/plugins/check_bacula) But this seems to stay green all the time. The log entries you see might be just from that check and not from the running backup, just intermingled within

Bug#1009231: Write errors since upgrade to 9.6.7-4

2022-04-15 Thread Klaus Ethgen
Hi Sven, Am Fr den 15. Apr 2022 um 10:52 schrieb Sven Hartge: > > Since upgrade from 9.6.7-3 to 9.6.7-4 I get many of the following errors > > in the log. However, the backup seems to work. > > > > JobId 0: Security Alert: bsock.c:380 Write error sending 4 bytes to > > client:127.0.0.1:57050: ER

Bug#1009231: Write errors since upgrade to 9.6.7-4

2022-04-15 Thread Sven Hartge
On 09.04.22 12:12, Klaus Ethgen wrote: Since upgrade from 9.6.7-3 to 9.6.7-4 I get many of the following errors in the log. However, the backup seems to work. JobId 0: Security Alert: bsock.c:380 Write error sending 4 bytes to client:127.0.0.1:57050: ERR=Broken pipe JobId 0: Security Alert: bs

Bug#1009231: Write errors since upgrade to 9.6.7-4

2022-04-09 Thread Klaus Ethgen
Package: bacula-director Version: 9.6.7-4 Severity: normal Since upgrade from 9.6.7-3 to 9.6.7-4 I get many of the following errors in the log. However, the backup seems to work. JobId 0: Security Alert: bsock.c:380 Write error sending 4 bytes to client:127.0.0.1:57050: ERR=Broken pipe JobId 0: