2008-01-08 Thread gregory
Will this correction be ported to the stable distribution. One of our production server with the myhuge.cnf has just hang up this morning. We just killed the find process. Preinst code: if [ -n `find $cvt_datadir -name '*.ISM' 2/dev/null` ]; then pidfile=`cvt_get_param pid-file`

Bug#453127: [debian-mysql] Bug#453127:

2008-01-08 Thread Norbert Tretkowski
Am Dienstag, den 08.01.2008, 09:29 +0100 schrieb gregory: Will this correction be ported to the stable distribution. One of our production server with the myhuge.cnf has just hang up this morning. We just killed the find process. It seems to affect more people than I initially thought, so I'll

Bug#453127: [debian-mysql] Bug#453127: mysql-common: preinst breaks on upgrade if datadir not set

2007-11-30 Thread Norbert Tretkowski
Am Dienstag, den 27.11.2007, 10:18 -0500 schrieb Edward Allcutt: I've also prepared a fix to the preinst which checks that the datadir exists before running find: Good catch, thanks. Patch applied. Norbert -- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of

Bug#453127: mysql-common: preinst breaks on upgrade if datadir not set

2007-11-27 Thread Edward Allcutt
Package: mysql-common Version: 5.0.32-7etch1 Severity: normal I run multiple mysqld instances on the same machine. Each uses a separate config file. None of them use /etc/mysql/my.cnf which doesn't exist on this system. On upgrade, the mysql-common preinst gets the datadir from