Bug#561369: does not collect hddtemp data

2009-12-18 Thread Yuri D'Elia
On Wed, 16 Dec 2009 20:04:11 +0100 Florian Forster o...@verplant.org wrote: Hi Yuri, thanks for the report. On Wed, Dec 16, 2009 at 06:15:21PM +0100, Yuri D'Elia wrote: - If I set TranslateDevicename false, I get two DBs: the 8-3 translated name *and* /dev/sda. Both contain NaNs

Bug#561369: does not collect hddtemp data

2009-12-16 Thread Yuri D'Elia
Package: collectd Version: 4.8.1-2 Severity: normal The hddtemp module seems to have some problems: - hddtemp is installed and correctly reporting data for /dev/sda, but the collected data is always NaN - If I set TranslateDevicename false, I get two DBs: the 8-3 translated name *and*

Bug#561369: does not collect hddtemp data

2009-12-16 Thread Florian Forster
Hi Yuri, thanks for the report. On Wed, Dec 16, 2009 at 06:15:21PM +0100, Yuri D'Elia wrote: - If I set TranslateDevicename false, I get two DBs: the 8-3 translated name *and* /dev/sda. Both contain NaNs instead of real values. Are both files updated or do you get a second file that is