26/06/2019 14:52, Burakov, Anatoly:
> On 26-Jun-19 1:36 PM, Bruce Richardson wrote:
> > On Wed, Jun 26, 2019 at 01:55:53PM +0200, Thomas Monjalon wrote:
> >> 26/06/2019 13:43, Burakov, Anatoly:
> >>> On 26-Jun-19 12:39 PM, David Marchand wrote:
> On Wed, Jun 26, 2019 at 1:36 PM Thomas Monjalon
On 26-Jun-19 1:36 PM, Bruce Richardson wrote:
On Wed, Jun 26, 2019 at 01:55:53PM +0200, Thomas Monjalon wrote:
26/06/2019 13:43, Burakov, Anatoly:
On 26-Jun-19 12:39 PM, David Marchand wrote:
On Wed, Jun 26, 2019 at 1:36 PM Thomas Monjalon wrote:
26/06/2019 13:20, David Marchand:
On Wed, J
On Wed, Jun 26, 2019 at 01:55:53PM +0200, Thomas Monjalon wrote:
> 26/06/2019 13:43, Burakov, Anatoly:
> > On 26-Jun-19 12:39 PM, David Marchand wrote:
> > > On Wed, Jun 26, 2019 at 1:36 PM Thomas Monjalon
> > > wrote:
> > >
> > >> 26/06/2019 13:20, David Marchand:
> > >>> On Wed, Jun 26, 2019 a
26/06/2019 13:43, Burakov, Anatoly:
> On 26-Jun-19 12:39 PM, David Marchand wrote:
> > On Wed, Jun 26, 2019 at 1:36 PM Thomas Monjalon wrote:
> >
> >> 26/06/2019 13:20, David Marchand:
> >>> On Wed, Jun 26, 2019 at 12:41 PM Thomas Monjalon
> >>> wrote:
> >>>
> When adding an alarm, if an er
On 26-Jun-19 12:39 PM, David Marchand wrote:
On Wed, Jun 26, 2019 at 1:36 PM Thomas Monjalon wrote:
26/06/2019 13:20, David Marchand:
On Wed, Jun 26, 2019 at 12:41 PM Thomas Monjalon
wrote:
When adding an alarm, if an error happen when registering
the common alarm callback, it is not consi
On Wed, Jun 26, 2019 at 1:36 PM Thomas Monjalon wrote:
> 26/06/2019 13:20, David Marchand:
> > On Wed, Jun 26, 2019 at 12:41 PM Thomas Monjalon
> > wrote:
> >
> > > When adding an alarm, if an error happen when registering
> > > the common alarm callback, it is not considered as a major failure.
26/06/2019 13:20, David Marchand:
> On Wed, Jun 26, 2019 at 12:41 PM Thomas Monjalon
> wrote:
>
> > When adding an alarm, if an error happen when registering
> > the common alarm callback, it is not considered as a major failure.
> > The alarm is then inserted in the list.
> > However it was retu
On Wed, Jun 26, 2019 at 12:41 PM Thomas Monjalon
wrote:
> When adding an alarm, if an error happen when registering
> the common alarm callback, it is not considered as a major failure.
> The alarm is then inserted in the list.
> However it was returning an error code after inserting the alarm.
>
8 matches