Ed Berezitsky created FLINK-36412:
-------------------------------------

             Summary: Retry strategies on Kinesis Sink
                 Key: FLINK-36412
                 URL: https://issues.apache.org/jira/browse/FLINK-36412
             Project: Flink
          Issue Type: Improvement
          Components: Connectors / AWS, Connectors / Kinesis
            Reporter: Ed Berezitsky


In case of internal Kinesis issues, Kinesis Sink connector crashes and causes 
application to stop

{{java.util.concurrent.CompletionException: 
org.apache.flink.kinesis.shaded.software.amazon.awssdk.core.exception.SdkClientException:
 Unable to execute HTTP request: connection timed 
out:<ACCOUNT_ID>.data-kinesis.us-west-2.amazonaws.com/<10.x.x.x>:443 at 
org.apache.flink.kinesis.shaded.software.amazon.awssdk.utils.CompletableFutureUtils.errorAsCompletionException(CompletableFutureUtils.java:65)
 at 
org.apache.flink.kinesis.shaded.software.amazon.awssdk.core.internal.http.pipeline.stages.AsyncExecutionFailureExceptionReportingStage.lambda$execute$0(AsyncExecutionFailureExceptionReportingStage.java:51)}}

 

The connector could introduce improved exception/error managing mechanism to 
allow an application to wait until connection is restored, controlled by 
additional parameters available for a users of the connector to set in a Flink 
aopp



--