Kostas Kloudas created FLINK-8522:
-------------------------------------

             Summary: DefaultOperatorStateBackend writes data in checkpoint 
that is never read.
                 Key: FLINK-8522
                 URL: https://issues.apache.org/jira/browse/FLINK-8522
             Project: Flink
          Issue Type: Bug
          Components: State Backends, Checkpointing
    Affects Versions: 1.4.0
            Reporter: Kostas Kloudas
            Assignee: Kostas Kloudas
             Fix For: 1.4.1


In the DefaultOperatorStateBackend at line 283 we write in the checkpoint an 
int declaring the number of the operator states that we include in the 
checkpoint. 

This number is never read when restoring and this can lead to confusion and 
problems with backwards compatibility and/or extension of the types of state we 
support (e.g. broadcast state).

There are two easy solutions, either remove the line and do not write the size, 
or make sure that we also read this number when restoring and simply ignore it.

I would go for the first one, i.e. remove the line. What do you think 
[~richtesn] and [~tzulitai] ?



--