Denis Magda created IGNITE-3191:
-----------------------------------

             Summary: BinaryObjectBuilder: binary schema id depends on the 
order of fields addition
                 Key: IGNITE-3191
                 URL: https://issues.apache.org/jira/browse/IGNITE-3191
             Project: Ignite
          Issue Type: Bug
            Reporter: Denis Magda
             Fix For: 1.7


Presently if an object is created using BinaryObjectBuilder then several 
BinarySchemes can be generated for the same set of fields in case when fields 
are added in a different order.

This happens because {{LinkedHashMap}} is used underneath. However we should 
rely on order-free structure like {{TreeMap}}.




--