Re: AW: Problems using WAP with siemens S35 /prev.(WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP / )

2002-03-04 Thread Aarno Syvänen
Hi, Bjoern Buettner wrote: ### 2002-03-02 19:46:08 [1] WARNING: Unknown content type 0x202 2002-03-02 19:46:08 [1] WARNING: Skipping faulty header 2002-03-02 19:46:08 [1] WARNING: Unknown content type 0x201 2002-03-02 19:46:08 [1] WARNING: Skipping faulty header 2002-03-02 19:46:08 [1]

Re: AW: Problems using WAP with siemens S35 /prev.(WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP / )

2002-03-04 Thread Stipe Tolj
Bjoern Buettner wrote: Oh guys, damn, I love Kannel, but I need a some working Siemens phones! :-)) stay cool, we'll get your loved Siemens phone to work! :)) How can I help. I'm not a C programmer, yet, but I want help, :-) I can't sleep while the problem is not solved !!! :-) I'll

Re: AW: Problems using WAP with siemens S35 /prev.(WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP / )

2002-03-04 Thread Stipe Tolj
Bjoern Buettner wrote: It seems to be a bug? with libxml, perhaps. I've two scenarios, a production environment a test environment. THE TEST SYSTEM: RedHat Linux 7.2 Kannel CVS version 2002/02/28 LibXML version libxml2-2.4.10-1 (devel XML Packet) THE PRODUCTION SYSTEM: RedHat

AW: AW: Problems using WAP with siemens S35 /prev.(WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP / )

2002-03-04 Thread Bjoern Buettner
An: [EMAIL PROTECTED] Cc: [EMAIL PROTECTED]; [EMAIL PROTECTED]; [EMAIL PROTECTED] Betreff: Re: AW: Problems using WAP with siemens S35 /prev.(WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP / ) Bjoern Buettner wrote: It seems to be a bug? with libxml, perhaps

AW: Problems using WAP with siemens S35 /prev.(WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP / )

2002-03-01 Thread Bjoern Buettner
. That's my new test version. ( I' hope I can be productive with this version very soon) Has anybody testet the Siemens ME45 mobile phone, successfully ? Please see Subject WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP / postings. The problem is unfortunately not solved, yet

Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-02-04 Thread Aarno Syvänen
Hi dark, Now, Kannel implements WSP 1.1 which does not define any Encoding-Version header. But because of all this, it might be better for Kannel send a status 400 error reply if a connect request uses unknown headers, rather than using the capabilities response to signal the problem and

Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-02-03 Thread Richard Braakman
I've seen this problem (or a similar one) before. I don't think it's a problem with the header decoding, because the phone goes into a timeout before the headers could have affected anything. In the case I saw, it was a problem with capabilities negotiation. The phone tried to open a

AW: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-02-01 Thread WERKSTUDENT1
[EMAIL PROTECTED] To: Bjoern Buettner [EMAIL PROTECTED] Cc: [EMAIL PROTECTED] Sent: Thursday, January 31, 2002 3:29 PM Subject: Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP / Bjoern Buettner wrote: I've configured the kannel WAP GW- in version cvs 30-dec

Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-02-01 Thread Bjoern Buettner
PROTECTED] Cc: [EMAIL PROTECTED] Sent: Friday, February 01, 2002 10:23 AM Subject: AW: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP / Hi! May I ask, what kind of timeout? Maybe you can send the log-information? Thanks, Marc -Ursprüngliche Nachricht- Von

WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP /

2002-01-31 Thread Bjoern Buettner
Sorry, I forget to say, Nokia 6210 (Browsers) works. Bjoern kind regards Vodafone TeleCommerce GmbH Architecture Engineering Bjoern Buettner Rehhecke 50 40885 Ratingen Tel. +49 (0) 21 02 / 97 20 13 Fax +49 (0) 21 02 / 97 15 14 mailto: [EMAIL PROTECTED] Internet: www.vodafone.com Internet:

Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 / Kannel WAP /

2002-01-31 Thread Andreas Fink
Hi guy's, I've configured the kannel WAP GW- in version cvs 30-dec.2001. Previous version of Kannel WAP was 1.0.5, it worked very fine. With the new version, we have some problems with SIEMENS S35 Phones. If I try to connect with the SIEMENS S35 to the gw, following error appears. 2002-01-31

Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-01-31 Thread Stipe Tolj
Bjoern Buettner wrote: I've configured the kannel WAP GW- in version cvs 30-dec.2001. Previous version of Kannel WAP was 1.0.5, it worked very fine. With the new version, we have some problems with SIEMENS S35 Phones. If I try to connect with the SIEMENS S35 to the gw, following error

Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-01-31 Thread Bjoern Buettner
] To: Bjoern Buettner [EMAIL PROTECTED] Cc: [EMAIL PROTECTED] Sent: Thursday, January 31, 2002 3:29 PM Subject: Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP / Bjoern Buettner wrote: I've configured the kannel WAP GW- in version cvs 30-dec.2001. Previous version

AW: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-01-31 Thread Bjoern Buettner
Nachricht- Von: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]Im Auftrag von Bjoern Buettner Gesendet: Donnerstag, 31. Januar 2002 16:27 An: Stipe Tolj Cc: [EMAIL PROTECTED] Betreff: Re: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP / Stipe wrote: AFAIK, phone.com did

Re: AW: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-01-31 Thread Stipe Tolj
Bjoern Buettner wrote: Has anybody a solution regarding my problem? are you sure your Siemens S35 does *not* receive the WML deck through kannel? You may provide my by private email the wml deck that you are trying to test against, if it is static, and I'll try this using our dedicated WAP

RE: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP /

2002-01-31 Thread erick.fuentes
[mailto:[EMAIL PROTECTED]] Sent: jueves, 31 de enero de 2002 14:42 To: Stipe Tolj Cc: [EMAIL PROTECTED] Subject: AW: WARNING: Skipping faulty header. / trouble with SIEMENS S35 /Kannel WAP / Hi again, I'm so sorry!!! What i want to say is, i did a mistake. Our production environment is Kannel WAP