Re: [OMPI devel] v1.5: sigsegv in case of extremely low settings in the SRQs

2010-06-23 Thread Shamis, Pavel
Good catch. The patch looks ok for me. Regards --- Pavel Shamis (Pasha) sham...@ornl.gov On Jun 18, 2010, at 11:10 AM, nadia.derbey wrote: > Hi, > > Reference is the v1.5 branch > > If an SRQ has the following settings: S,,4,2,1 > > 1) setup_qps() sets the following: > mca_btl_openib_compone

[OMPI devel] v1.5: sigsegv in case of extremely low settings in the SRQs

2010-06-18 Thread nadia.derbey
Hi, Reference is the v1.5 branch If an SRQ has the following settings: S,,4,2,1 1) setup_qps() sets the following: mca_btl_openib_component.qp_infos[qp].u.srq_qp.rd_num=4 mca_btl_openib_component.qp_infos[qp].u.srq_qp.rd_init=rd_num/4=1 2) create_srq() sets the following: openib_btl->qps[qp].u.