AW: [development-axapta] Axapta Code Protection - Source Scrambling

2006-02-03 Thread Leberbauer Herbert - News
Besides I have to say, that this kind of scrambling can be done by any Axapta-Programmer himself. Tobias' statement has also to be kept in mind - Axapta's power is the possibility to read the code. Regards Herbert -Ursprüngliche Nachricht- Von: development-axapta@yahoogroups.com

AW: [development-axapta] Server setup??

2005-10-10 Thread Leberbauer Herbert - News
For Axapta 3.0 SP4 it is Windows Server 2003 w SP1. Look for the paper which is talking about hardware sizing. Regards Herbert -Ursprüngliche Nachricht- Von: development-axapta@yahoogroups.com [mailto:[EMAIL PROTECTED] Im Auftrag von Andre Klopper Gesendet: Montag, 10. Oktober 2005

[development-axapta] How to connect to Axapta Installations for Data-Exchange

2005-08-08 Thread Leberbauer Herbert - News
Hello! Is there someone out there who has ever made a connection between two different Axapta-Installations (yes, 2 DBs and 2 Appl-Folders), to establish some kind of data exchange. We want to do the following: We have two installations (different DB-Server, different AOS, different

AW: [development-axapta] Axapta Replication

2005-06-20 Thread Leberbauer, Herbert - News
Hi Samuel, I think the answer is dependent on what kind of data you want to replicate. So I would say, it will definitely be possible to replicate the data, BUT I would also say, you really have to think about why and what you want to replicate. regards Herbert | -Ursprüngliche

AW: [development-axapta] Login to axapta 2.5 - Insufficient access codes ?

2005-05-24 Thread Leberbauer, Herbert - News
Maybe the user wants to log on to a Axapta-Application-layer different from the USR-Layer and no code is entered in the AxConfig? | -Ursprüngliche Nachricht- | Von: development-axapta@yahoogroups.com | [mailto:[EMAIL PROTECTED] Im Auftrag von jaren chia | Gesendet: Dienstag, 24. Mai

AW: AW: [development-axapta] thin /fat, 2-tier/3-tier combination

2005-05-24 Thread Leberbauer, Herbert - News
, | | It is a question from Ax Certification. Thanks a lot man. | | Richard | | --- Leberbauer, Herbert - News | [EMAIL PROTECTED] wrote: | | Hi ?! | | Is this a question from a certification test? | | I would say the correct answer is d. If you have an AOS then | everybody should use it, no matter if fat

AW: [development-axapta] thin /fat, 2-tier/3-tier combination

2005-05-23 Thread Leberbauer, Herbert - News
Hi ?! Is this a question from a certification test? I would say the correct answer is d. If you have an AOS then everybody should use it, no matter if fat or thin client. HTH Herbert | -Ursprüngliche Nachricht- | Von: development-axapta@yahoogroups.com | [mailto:[EMAIL PROTECTED]

AW: [development-axapta] Com objects and mailing

2005-05-18 Thread Leberbauer, Herbert - News
Hi Daniel, I think the problem is, that very much functionality, which is placed outside Axapta, but used by Axapta, wants to be controlled with COM-objects. So I think this is a general problem for your environment, isn't it? I am interested why you don't want to use COM? Regards Herbert

[development-axapta] Axapta Version 2.5 on MS SQL 2000 with SP3a

2005-03-30 Thread Leberbauer, Herbert - News
Hi! We want to install a new server for our customer and want to install Windows Server 2003 and SQL 2000 SP3a. The customer is using Axapta 2.3 with SP3, in 2-tier mode. Are there any problems? Anything to think about? regards Herbert Yahoo! Groups Sponsor ADVERTISEMENT

AW: [development-axapta] Fielproperties

2005-03-29 Thread Leberbauer, Herbert - News
Hi Jesper! Your database is already caseINsensitive (the ..._CI_... in Latin1_genarel_CP1_CI_AS means CaseInsensitive). HTH Herbert | -Ursprüngliche Nachricht- | Von: [EMAIL PROTECTED] | [mailto:[EMAIL PROTECTED] | Gesendet: Dienstag, 29. März 2005 10:45 | An:

AW: [development-axapta] Terminal server/Printer

2005-03-29 Thread Leberbauer, Herbert - News
Do they use AOS? If not, their Data-Center-Provider should check his ActiveDirectory-Permissions. HTH Herbert | -Ursprüngliche Nachricht- | Von: henrikjensen2 [mailto:[EMAIL PROTECTED] | Gesendet: Dienstag, 29. März 2005 10:47 | An: development-axapta@yahoogroups.com | Betreff:

AW: [development-axapta] Re: Terminal server/Printer

2005-03-29 Thread Leberbauer, Herbert - News
, they use AOS. | | Best regards, | Henrik | | | | --- In development-axapta@yahoogroups.com, Leberbauer, | Herbert - News [EMAIL PROTECTED] wrote: | | Do they use AOS? | | If not, their Data-Center-Provider should check his | ActiveDirectory-Permissions. | | HTH | Herbert

AW: [development-axapta] Fielproperties

2005-03-29 Thread Leberbauer, Herbert - News
attachments is | confidential. The information must only be held in areas that | have controlled and limited access to the addressed persons. | If this e-mail has been sent to you in error, please | immediately notify the sender and delete the e-mail. Thanks. | | _ | | Von: Leberbauer, Herbert

AW: [development-axapta] Axapta 3.0 Installation - ODBC (To use or not to use)

2005-03-08 Thread Leberbauer, Herbert - News
I can only speak for MSSQL: If you don't establish a system dns, Axapta will do for you, so it just does some work for you, but it's the same if you use the datasource-field in your axconfig or not. There's no performance advantage. For oracle, there are big differences, but I don't know

AW: [development-axapta] Changecompany

2005-03-07 Thread Leberbauer, Herbert - News
This seems ok to me. Which code do you execute in your changecompany-clause? Where did you instantiate your table variables? Herbert | -Ursprüngliche Nachricht- | Von: Matt Benic [mailto:[EMAIL PROTECTED] | Gesendet: Montag, 07. März 2005 09:52 | An: Axapta Dev | Betreff:

AW: [development-axapta] Changecompany

2005-03-07 Thread Leberbauer, Herbert - News
| www.smallfrymobile.com http://www.smallfrymobile.com | | | -Original Message- | From: Leberbauer, Herbert - News [mailto:[EMAIL PROTECTED] | Sent: 07 March 2005 11:57 AM | To: development-axapta@yahoogroups.com | Subject: AW: [development-axapta] Changecompany | | | | | This seems ok to me

AW: AW: [development-axapta] Terminal or citrix server

2005-02-18 Thread Leberbauer, Herbert - News
@yahoogroups.com | Betreff: Re: AW: [development-axapta] Terminal or citrix server | | | | We connect with terminal services but are experiencing | problems with duplicate and triplicate printing. Do you know | where there might be info on how to stop this? | | Thanks, Michelle | | Leberbauer, Herbert

AW: [development-axapta] TransactTxt

2005-02-09 Thread Leberbauer, Herbert - News
Hi Jens, I don't know which text-field you mean, but most of the text-fields in Axapta can only have ONE format, e.g. everything bold, or nothing. Herbert | -Ursprüngliche Nachricht- | Von: Jens Strandberg [mailto:[EMAIL PROTECTED] | Gesendet: Mittwoch, 09. Februar 2005 14:22 |

AW: [development-axapta] connectivity studio

2005-02-09 Thread Leberbauer, Herbert - News
Hi Willie! I only know, that it's some kind of connector to put data from or to Axapta. Reminds me of MS Biztalk. Why do you care about that? What do you need? Herbert | -Ursprüngliche Nachricht- | Von: willem_baelde [mailto:[EMAIL PROTECTED] | Gesendet: Mittwoch, 09. Februar

AW: [development-axapta] Re: Passing more than one parameters to a form

2005-02-08 Thread Leberbauer, Herbert - News
How about that: Write a class (MyClass) with a method which only returns your container, e.g. container parmMyContainer(container _myContainer = myContainer) { return [value1, value2,...]; } Then send this class within your args to your form, e.g. Args args = new Args(NameOfYourClass);

AW: [development-axapta] Re: Server/Client Problem

2005-02-02 Thread Leberbauer, Herbert - News
Hi, did you take care of the filepaths you are using? You should use UNC-paths (e.g. \\Axapta-Server\myFolder) Because if you use e.g. c:\myTempFolder as the path in your code, it's a difference if the code is executed on the AOS or if executed on the client. The path may exist on your

AW: [development-axapta] Label Files

2005-02-01 Thread Leberbauer, Herbert - News
In the same place as in 2tier (in the Standard-folder) /Herbert | -Ursprüngliche Nachricht- | Von: RFK142 [mailto:[EMAIL PROTECTED] | Gesendet: Dienstag, 01. Februar 2005 11:28 | An: development-axapta@yahoogroups.com | Betreff: [development-axapta] Label Files | | | | |

AW: [development-axapta] Axapta and Citrix

2005-01-20 Thread Leberbauer, Herbert - News
Hi Gerhard, there are a lot of Axapta-Installations using Citrix as Terminalserver out there. Also the good old Windows Terminal Services are commonly used, especially our customers are using it (because it's cheaper). I heard about some problems with Citrix and Axapta (read in this

[development-axapta] Security on Print Archive

2004-11-10 Thread Leberbauer, Herbert - News
Hello! We have the following problem: Our customer wants to print reports to the print archive. But those reports have security-settings, so that only people with granted access may use that reports. But when the report is printed to the print archive, the security permissions are gone. Any

AW: [development-axapta] Print two-three pages of text in a report

2004-10-15 Thread Leberbauer, Herbert - News
Hi Irving, I only have a method on resolution, which is not with regard to Axapta (but it's realizable with Axapta): So on every record on the report I would make a while-loop which prints a field of fixed length, and this field will be filled with text portions of your big memo-field, and

[development-axapta] EditorScripts

2004-10-07 Thread Leberbauer, Herbert - News
Hi! Has anyone developed any Editor-Scripts for generating the Find() and Exist()-Method for a Maintable? best regards Herbert Yahoo! Groups Sponsor ADVERTISEMENT Yahoo! Groups Links To visit your group on the web, go

[development-axapta] Find the name of an object?

2004-07-26 Thread Leberbauer, Herbert - News
Hi! In Ax 2.5 SP4 I want to modify the Dialog-Class in the New()-Method, so I can see the name of the caller. I would like to have something like ... info(strfmt(The name of the caller is %1,_caller.tostring())); ... But I always get some stacktrace-errors. Is there another way to do