On Wed, Jan 06, 2016 at 08:25:21AM -0600, Rob Herring wrote:
> On Wed, Jan 06, 2016 at 12:37:35PM +, Mark Brown wrote:
> > > I tried to roundoff to the next higher threshold when supported value (120
> > > or 140 degC) is not provided in driver. But it is fine to me to specify
> > > the
> > >
On Wednesday 06 January 2016 07:55 PM, Rob Herring wrote:
On Wed, Jan 06, 2016 at 12:37:35PM +, Mark Brown wrote:
On Wed, Jan 06, 2016 at 05:49:22PM +0530, Laxman Dewangan wrote:
On Wednesday 06 January 2016 05:48 PM, Mark Brown wrote:
* PGP Signed by an unknown key
On Wed, Jan 06, 2016 a
On Wed, Jan 06, 2016 at 12:37:35PM +, Mark Brown wrote:
> On Wed, Jan 06, 2016 at 05:49:22PM +0530, Laxman Dewangan wrote:
> > On Wednesday 06 January 2016 05:48 PM, Mark Brown wrote:
> > >* PGP Signed by an unknown key
>
> > >On Wed, Jan 06, 2016 at 11:45:22AM +0530, Laxman Dewangan wrote:
>
On Wednesday 06 January 2016 06:07 PM, Mark Brown wrote:
* PGP Signed by an unknown key
In one of design, interrupt from MAX77620, and alert from both MAX77621
shorted and going to Arm GIC controller. On this case, I need to register
the interrupt as SHARED interrupt. This property can not be
On Wed, Jan 06, 2016 at 05:49:22PM +0530, Laxman Dewangan wrote:
> On Wednesday 06 January 2016 05:48 PM, Mark Brown wrote:
> >* PGP Signed by an unknown key
> >On Wed, Jan 06, 2016 at 11:45:22AM +0530, Laxman Dewangan wrote:
> >> Enhanced transient response (ETR) will affect the configuration o
On Wednesday 06 January 2016 05:48 PM, Mark Brown wrote:
* PGP Signed by an unknown key
On Wed, Jan 06, 2016 at 11:45:22AM +0530, Laxman Dewangan wrote:
Enhanced transient response (ETR) will affect the configuration of CKADV.
+-maxim,junction-temp-warning: Junction temp warning on which de
On Wed, Jan 06, 2016 at 11:45:22AM +0530, Laxman Dewangan wrote:
> Enhanced transient response (ETR) will affect the configuration of CKADV.
> +-maxim,junction-temp-warning: Junction temp warning on which device generates
> + warning interrupts.
This needs to specify what the values
The driver MAX8973 supports the driver for Maxim PMIC MAX77621.
MAX77621 supports the junction temp warning at 120 degC and
140 degC which is configurable. It generates alert signal when
junction temperature crosses these threshold.
MAX77621 does not support the continuous temp monitoring of