Re: [Drakelist] TR-7 S meter issue

2009-02-20 Thread David & Chris Drake
Book". 73's David - Original Message - From: "Jim Shorney" To: ; "David & Chris Drake" Sent: Thursday, February 19, 2009 11:30 PM Subject: Re: [Drakelist] TR-7 S meter issue On Thu, 19 Feb 2009 17:44:59 -0500, David & Chris Drake wrote: Anyway, I&#

Re: [Drakelist] TR-7 S meter issue

2009-02-19 Thread Jim Shorney
On Thu, 19 Feb 2009 17:44:59 -0500, David & Chris Drake wrote: >Anyway, I'm gonna study up on the 2nd if-audio board and see if I can figure >out anything. Here it is: http://radiojim.exofire.net/pages/TR7_2IFA.html I hope this is helpful to you. 73 -Jim -- Ham Radio NU0C TR7/RV7/R7A/L7,

Re: [Drakelist] TR-7 S meter issue

2009-02-19 Thread David & Chris Drake
can figure out anything. Later, David - Original Message - From: "Jim Shorney" To: Sent: Thursday, February 19, 2009 5:11 PM Subject: Re: [Drakelist] TR-7 S meter issue On Thu, 19 Feb 2009 10:45:37 -0500, David & Chris Drake wrote: I've gone over the S-meter setup

Re: [Drakelist] TR-7 S meter issue

2009-02-19 Thread Jim Shorney
On Thu, 19 Feb 2009 10:45:37 -0500, David & Chris Drake wrote: >I've gone over the S-meter setup 3 times, and same result. An S-9 signal is >30 over, calibrate is about the same, 30 over. I've tried a separate signal >generator at 50mv and its 30+ over (elecraft oscillator). Same 50mv signal

[Drakelist] TR-7 S meter issue

2009-02-19 Thread David & Chris Drake
Hi, maybe someone on the list can help me troubleshoot this. My TR-7 is now working VG+ with with one exception. the S meter reads way high on receive. Wattmeter portion is correctly set per manual, and all other receive alignments are spot on per the manual. I've gone over the S-meter se