Re: [PATCH] rtl8188eu: fix signal strength indication

2016-02-15 Thread Andrew Bradford
Hi Larry, On 02/13 13:50, Larry Finger wrote: > On 02/11/2016 07:38 PM, Andrew Bradford wrote: > >RTL8188E can only have a maximum of 2 chains so match that in the actual > >phy_rx_agc_info structure within phy_status_rpt. This will cause the > >other data received from the PHY, such as signal st

Re: [PATCH] rtl8188eu: fix signal strength indication

2016-02-13 Thread Larry Finger
On 02/11/2016 07:38 PM, Andrew Bradford wrote: RTL8188E can only have a maximum of 2 chains so match that in the actual phy_rx_agc_info structure within phy_status_rpt. This will cause the other data received from the PHY, such as signal strength indication of beacons, to properly align and allo