This is caused by elasticsearch trying to load fielddata. Fielddata is used
for sorting and faceting/aggregations. When a query has a sort parameter
the node will try to load the fielddata for that field for all documents in
the shard, not just those included in the query result. The breaker is
I'm still having this problem... has anybody got an idea what the cause /
solution might be?
Thank you! :)
On Tuesday, 7 October 2014 14:29:22 UTC+2, Robin Clarke wrote:
I'm getting a lot of these errors in my Elasticsearch logs, and am also
experiencing a lot of slowness on the cluster...
I'm getting a lot of these errors in my Elasticsearch logs, and am also
experiencing a lot of slowness on the cluster...
New used memory 7670582710 [7.1gb] from field [machineName.raw] would be
larger than configured breaker: 7666532352 [7.1gb], breaking
...
New used memory 7674188379 [7.1gb]