I've had fun putting together K2 #7373, and am finally at the point of doing
the 40-Meter Transmitter Alignment (manual, p.78). I have the unit connected
to a 50-ohm dummy load, and am trying to tune L1 and L2 to show 2W on the
internal wattmeter. When I press TUNE, the measured power ranges
On Oct 27, 2012, at 6:23 PM, Don Wilhelm wrote:
>> On 10/27/2012 7:44 PM, Ben Byer wrote:
>> I've had fun putting together K2 #7373, and am finally at the point of doing
>> the 40-Meter Transmitter Alignment (manual, p.78). I have the unit
>> connected to a 50-
On Oct 28, 2012, at 5:51 AM, Mike K8CN wrote:
> It sounds like re-heating of the solder connections on both sides of C121 is
> in order. The fact that your RF voltage on terminal 3 of T1 has the proper
> ratio to that on terminal 1 implies that T1's solder joints are OK. The
> absence of RF on
3 matches