Hi Keith,
Thanks for your comments and also to several others who replied
privately. I have now resolved the fault that was causing the +270v T/R
bias line to be shorted and the 270v ERR hard fault to show.
As several others have discovered with the same fault, the problem was
C2, a faulty
I wonder if anyone can offer some advice please?
I've just put together a KPA-500 linear amplifier kit and everything
seemed to work fine until I switched from standby to operate when I get
a 270v ERR message, which needs a hard reset.
The 60v line is present (68.5v) and the interlock works as
2 matches