APF and my 2 cents - I was using predefined NORM II settings for APF, if
needed.
The problem (my problem) is that I am using 200Hz filter in my S&P operation
but for APF I use 400Hz filter. (it was my chioce - YMMV of course...)
By switching on APF directly by holding XFIL button it will stay on c
Hi Dick,
good idea! I have to check N1MM and K3 Macros docs.
(or any ready-made such a macro to copy/paste?)
But still fw option is fw option
-dst-
-- Původní zpráva --
Od: Dick Dievendorff
Komu:
Datum: 9. 1. 2015 22:03:59
Předmět: Re: [Elecraft] K3: Option: power
Hi OMs,
let me ask if anybody will consider folowing as useful Option (option - used
when needed :-)):
- in K3 with KAT3 ATU unit (it means with 2 ant outputs ANT1/ANT2) to have
possibility of different output power set by ANT port.
Simply in menu CONFIG: PWR SET new option PER-ANT
Why? If I hav
HI David,
so my numbers:
for 144.300MHz
0,1mW -> 2W out
1mW -> 9W
for 146.100MHz (as I have I/F for 10GHz from 146MHz up)
0,1mW -> 1,3W
1mW -> 7W
hope You did power calibration via K3 Utility whwre is also 1mW output
calibration
(I did ;-))
All the best and GL,
73!
Lexa, OK1DST
K3/100 #727
Hi Russ,
the same problem was here with BC station abt 5km away. Only with KPA in the
chain.
What helps - increasing current in diode switch on KPA board - change of R25
to cca 65 Ohm and there are no IMD products as before.
Hope this can help in any similar case in very special configuration of
Hi Mike,
if You open some mail-archive You can see a lot of mails concerning this
behaviour (recognized as strange by some of us) from the first days of K3.
There is probably no way for solution. So if You have key activated You have
a Key Out activated. There is no real PTT out. Probably this w
6 matches