Group,
I don't seem to have the steps by which one sets the KXV3's output to
1.00 mw for use with XV144..
Here is what I've tried: (1) Set Band to 28 MHz. (2) Set CONFIG to
TEST in KVX3, (3) Set power to 1.00 mw, (4) Hold TUNE. After a moment, the
display changes from 1.00
Group,
Two questions:
Group
1) How do I get stereo output from the stereo output jack?
2) How do I change the mode reading from "reverse data" to plain :"data" so
that it stays that way if I turn the K3 off. I know how to change it, but my
K3 seems to be suffering from "recent memor
When I work DX, I like to listen to VFO B and VFO A at the same time, but
at different volume levels. I want to hear the DX call me on VFO A and I like
to find an open spot on VFO B where everyone is calling the DX station.
Can I do that with my K3? I don't see any obvious way, other
While trying to set up my K3's low level output for use with my Elecraft
144 MHz Transverter, I have inadvertently screwed up my K3 system. Now I am
getting the "ERR PL2" message. How did I do that?
So, I need two things: First, how do I correct this error? That is, what
are the spec
What is the difference between the Elecraft MH2 Hand mike and the
Elecraft MD2 mile in the Stainless Steel case and Heil logo at the bottom? Are
they both direct plug-in to the K3? Are they both electret elements? I seem to
get a bit more punch from the hand mike MH2.
What is the difference between the Elecraft MH2 Hand mike and the Elecraft MD2
mile in the Stainless Steel case and Heil logo at the bottom? Are they both
direct plug-in to the K3? Are they both electret elements? I seem to get a bit
more punch from the hand mike MH2.
Glienn ON4WIX,
Thanks for the tip. Tapping DISP did the trick! Now
everything is working.
Roger K8RS
___
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to
K3 #280 ordered on May 14th with deposit, arrived in Okemos, Michigan
on January 28th.
I completed the assembly and calibration on Wednesday with some advice
and counsel from Gary. Yesterday, I made up a cable to obtain Band Data and
FSK from the 15 pin Aux/IO terminal. I now h
Gurus,
I am in the Alignment Procedure Part I on the 144 MHz Transverter
(page 59). After the unit has been on for an hour or more, the voltage reading
on TP1--testing the local oscillator voltage--varies between 0.002 and 1.642
vdc.
When I first turn the unit on using the K2,
Gurus,
I am beginning the Alignment Procedure Part I on the 144 MHz
transverter and getting a strange reading at TP1 when conducting the test on
the local oscillator ( page 59). The voltage seems to be varying between 0.002
and 1.642 vdc. The oscillator seems to be going in and out
10 matches
Mail list logo