The remaining tin-plated connectors are not a problem because both the pins
and sockets are the same metal.
The problem with the replaced connectors is that the sockets were tin-plated
and the pins were gold-plated (maybe the other way around). Over time the
dissimilarity of these two metals
No more issues
K3 #1255
73
Arie PA3A
---
Dit e-mailbericht is gecontroleerd op virussen met Avast antivirussoftware.
https://www.avast.com/antivirus
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
I agree with Ken #2652
--
View this message in context:
http://elecraft.365791.n2.nabble.com/K3-Gold-Plated-Plug-Replacment-tp7616531p7616533.html
Sent from the Elecraft mailing list archive at Nabble.com.
__
Elecraft mailing list
I have K3 #202 and over the years I
replaced all of the pin connectors that
were recommended by Elecraft. I have had
no issues after installing the
replacements connectors.
73, Ken K3IU
~~
On 4/20/2016 8:27 AM, David Robertson wrote:
Everyone,
I have
Everyone,
I have an old K3 ( Serial # 934 ) and was starting to be plagued by
interconnection problems inside of my K3 caused by the tin plated plugs.
After contacting Elecraft I received 2 connector kits. One for the 100 watt
power amp connections ( KPA3 ) and one for the front panel ( J30 and