Re: [Elecraft] [elecraft] PX3 Firmware 1.39 General Release

2015-11-13 Thread JE0LFI
Hi Paul My PX3 has been reset(MENU and PWR). REF and SCALE is OK, but waterfall high is not saved. I set waterfall hight=138 and Auto text mode=ON. In 40m, VFO A and MODE=LSB, waterfall display hight is collect(hight=138). When I change VFO B(MODE=CW), text area hight is collect. When I

Re: [Elecraft] [elecraft] PX3 Firmware 1.39 General Release

2015-11-09 Thread Paul Saffren N6HZ
Nakamura, Please try a parameter reset on the PX3 and see if that solves the problem. If you upgraded from 1.35/1.37 there may be a need to perform the reset. This can be accomplished by holding the MENU key and tapping the POWER key. Kind regards, Paul -- View this message in

Re: [Elecraft] [elecraft] PX3 Firmware 1.39 General Release

2015-11-06 Thread JE0LFI
Dear n6hz Paul Setting value: REF, Scale, Waterfall high etc could not save correctly(only 40m?). Best regards, JE0LFI nakamura -- View this message in context: http://elecraft.365791.n2.nabble.com/PX3-Firmware-1-39-General-Release-tp7610017p7610078.html Sent from the Elecraft mailing list