Evert,
Take a look at KPA100 resistors R19 and R20. If they have blue-gray
bodies, they are likely to be inductive (which causes the problem you
mentioned).
The new non-inductive resistors have reddish-brown bodies andcan be
obtained by a note to [EMAIL PROTECTED]
Now off to more FDIM/Day
Hello,
I do have a K2 and KPA 100 (build-in).
For some reason I do get HiCurr messages on a few band (which I didn't get
before)
I did a test with a dummy (50 Ohm up to 1 Ghz) and a Bird 43 power meter
The result is:
28.500 12,3V / 2,66A 100W+
24.900 12,3V / 2,44A 100W+
21.1
2 matches