[Elecraft] K2 - KPA100 down again

2008-07-07 Thread nz0t
After performing flawlessly for over a year my KPA100 has died for the second time in about 3 months. I was finishing a nice 20 minute QSO on 10M CW last week when the rig's lights flickered and the power supply shut down. Now the power cord fuses blow and there appears to be a short when the po

Re: [Elecraft] K2 - KPA100 down again

2008-07-07 Thread Kurt Cramer
gt; To: Sent: Monday, July 07, 2008 4:24 PM Subject: [Elecraft] K2 - KPA100 down again After performing flawlessly for over a year my KPA100 has died for the second time in about 3 months. I was finishing a nice 20 minute QSO on 10M CW last week when the rig's lights flickered and the po

Re: [Elecraft] K2 - KPA100 down again

2008-07-07 Thread Don Wilhelm
Bill, Remove the shield and give it a good visual inspection first - look for any evidence of overheated components. Then check the diodes in the T/R switch - preferably with a diode test function of a DMM, but the ohmmeter will work too - check both the forward and reverse connections. Check

Re: [Elecraft] K2 - KPA100 down again

2008-07-08 Thread nz0t
Thanks Don, I checked the diodes and D12 and D14 in the switching circuit tested bad along with D10 in the 12V line. However when I took them out they all tested OK. I replaced them with new and now D12 and D14 tst OK in circuit but D10 still shows bad but is OK once taken out of circuit. Needl