Todd, that sounds like a noisy pot in which the wiper isn't making good
contact with the resistive element inside. When you touch it, the circuit
opens briefly, which is the same as turning the RF Gain all the way to
minimum. That will cause the S-meter to read full scale. The delay returning
to
Thanks Tom,
I suspect the gain pot is defective. I will check soldering also. I'll get
an RF gain pot on the way and try swapping it out also.
Todd
___
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to
Spraying the chemical onto/into a Q-tip and
then squeezing it out by pressing the cotton
against the upward-pointing shaft will avoid the
splattering.
73! Ken Kopp - K0PP (K2 #5665)
[EMAIL PROTECTED]
or
[EMAIL PROTECTED]
___
Elecraft mailing list
The lube is a good place to start Ron. Thanks. I have noticed that just
touching the RF knob causes this to happen so you are probably on to
something here. I don't have a lube other than tri-flow but will look for
something like what you mentioned. Todd
-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Todd Gahagan
Sent: Sunday, February 18, 2007 10:18 AM
To: Elecraft Reflector
Subject: [Elecraft] K2 RF Gain Control question
I just noticed that whenever I touch my RF gain control knob for adjustment
the S meter jumps completely