--- David Cutter <[EMAIL PROTECTED]> wrote:
> Glad you raised that point, Brian. In my Sunday
> school classes I ask the
> question: "what does the fuse protect?" It's a
> revelation to all when I
> give the right answer.
>
> On our 240V distribution system, a melted cable can
> lead to a s
Glad you raised that point, Brian. In my Sunday school classes I ask the
question: "what does the fuse protect?" It's a revelation to all when I
give the right answer.
On our 240V distribution system, a melted cable can lead to a severe shock
hazard and I'm guessing that in the 110V centre-
On Jun 16, 2008, at 9:59 PM, <[EMAIL PROTECTED]> <[EMAIL PROTECTED]
> wrote:
A regular fuse should blow at 2.6 x the rating within 30s, in other
words very slowly. It's only a short circuit that will normally
blow a new fuse. Have not seen any data on old fuses which might
get metal fa
Hi Ron,
Thanks for the analysis. You pointed out several
things I was unaware of related to these types of
fuses. Nice to learn something new!
I'm in the process of redoing the power distribution
in my shack, so will take this info into account.
Fortunately, it's been a while since I've blown an
legs anyway...
David
G3UNA
>
> From: "Ron D'Eau Claire" <[EMAIL PROTECTED]>
> Date: 2008/06/16 Mon PM 06:52:16 BST
> To: "'Elecraft Discussion List'"
> Subject: RE: [Elecraft] K3: Power cable question
>
> Hi Julius:
>
> I meas
Hi Julius:
I measure just over 20 Amps under some bands and conditions running the K3
at 100 watts. Like the K2, I suspect the current draw varies a bit depending
upon the rig, the actual parameters of some of the transistors, etc. That's
normal, according to the K3 specs, which rate the current d
Ron,
I've been using my K2 cable with my K3, including
contests, without an issue.
Considering what the KPA100 will do with my 160M
setup, in the way of drawing current, I think there is
enough wiggle room not to worry too much.
The K3 barely gets warm when I run :o)
73,
Julius
Julius Faze
Me too, but I realized that the K3 draws somewhat more current than the
K2/100. Depending upon the band antenna, etc., the total current can exceed
the rating of the rating of the 20-amp fuse in the K2/100 power cord.
Ron AC7AC
-Original Message-
> ...whether the K2/100 power cable is i
...whether the K2/100 power cable is interchangeable with
the K3/100 (i.e. do the Andersons have the same orientation
on K2 and K3)?
Yes, they have the same orientation. I initially ran my K3 with my
K2/100 cable.
73,
Lyle KK7P
___
Elecraft mail
I haven't been able to locate this information in the documentation, so perhaps
a kind soul could oblige?
In anticipation of a K3/100 kit's arrival, I would like to know the length of
power cord supplied and also whether the K2/100 power cable is interchangeable
with the K3/100 (i.e. do the And
10 matches