I'm having a power out problem with the K3 when using the KPA500 and Writelog software for SO2V (NOT SO2R) operation. Normally when I put the KPA500 in operate the power out setting on the K3 drops to the normal 23-28 watts needed to drive the KPA500. Intermittently when changing VFO's and RX the power will come up at 100 watts and fault the KPA500. If i put the KPA500 back in opeatate the next tx will work fine. I have noticed this problem going from VFOA to VFOB (going to split) and the other way as well. What am I doing wrong? It works most of the time! Out of about 50 switches this weekend, only 4 overdrive faults on the amp. (only ran 3 hours so only 90 contacts).
Writelog version 11.02A, K3 SN:5651 MCU 4.39 FPF 1.14 DS1 2.73 DSP2 2.73, KPA500 FW 1.11, P3 FW 1.12 Thanks! Gordon - N1MGO ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html