Re: [Elecraft] K3 Fuse Blowing on Power Supply

2023-05-06 Thread W3FPR
Bill, The K3 will draw between 17 and 22 amps during transmit.  That 15 amp fuse is too small,  increase it to 25 amps.  Hopefully your power supply is capable of 25 amps or more. Use a power supply that has 14.3 volts output if you can.  Not only will your TX be cleaner (lower IMD), but the c

Re: [Elecraft] K3 Fuse Blowing on Power Supply

2023-05-06 Thread David Olean
There is an over voltage protection diode inside. Maybe it was tripped? Easy to replace.. I think it is right rear when looking from the top and front of the radio. Just a short HV spike can trigger that diode. You can find it on the K3 schematic. Dave K1WHS On 5/6/2023 2:30 PM, Bill Gillenwa

[Elecraft] K3 Fuse Blowing on Power Supply

2023-05-06 Thread Bill Gillenwater
Current setup. K3 with P3 early serial. Back to factory for complete update. Gold Pins etc. Today K3 shut down. Found blown 15 amp fuse in ground side of power supply cable Power supply is MFJ 4035MW. Have had no previous problems with this setup. Occasionally there was a message on the K3 saying