At the antenna spigot.
On 1/23/2019 10:00 AM, Phil Hystad via Elecraft wrote:
If I had an S-meter reading, S9 for example, on my K3, what could I infer about
the voltage level of that signal at the Coax input to my K3?
A table I found on the Internet for singals below 30 MHz says that an S-9 m
Phil,
With the original K3, S Meter "ABS" mode the S meter is referenced to
the signal level at the antenna jack. S9 = -73 dBm = 50 uV into 50 ohms.
In the other S Meter mode, the reading varies with ATT and PRE settings,
as well as signal level.
73,
Lyle KK7P
On 1/23/19 10:00 AM, Phil H
If I had an S-meter reading, S9 for example, on my K3, what could I infer about
the voltage level of that signal at the Coax input to my K3?
A table I found on the Internet for singals below 30 MHz says that an S-9 meter
reading is a signal of 50-microvolts but where in the system is that
regis
3 matches