Thank you Bob and Bart. I will contact Support asap. 73, Mike K0AZ
On 8/25/2019 10:50 AM, Bart Campbell wrote:
I agree with Bob. This exact problem occurred with my KPA500 last year
and it was the switching diodes. Support offered to send the parts for
me to replace but I opted to send the
I agree with Bob. This exact problem occurred with my KPA500 last year and
it was the switching diodes. Support offered to send the parts for me to
replace but I opted to send the amp in for repair. Support was a pleasure
to deal with.
73,
Bart, NS4X
On Sunday, August 25, 2019, Mike Sanders
As I've read earlier, likely an issue with the T/R switching diodes in
the amp. Contact Tech Support at Elecraft.
73
Bob, K4TAX
On 8/25/2019 8:17 AM, Mike Sanders wrote:
Probably a cable mess up on my part. Before I go through heroic
efforts to
move the operating desk can anyone offer
Probably a cable mess up on my part. Before I go through heroic efforts to
move the operating desk can anyone offer any help or advice.
The receiver is fine when the KPA500 is turned on but in STBY. When it is
switched to OPER the RX drops from say S9 to S3. Any ideas?
Thanks, Mike K0AZ