On 9/18/2018 6:15 AM, Bob McGraw K4TAX wrote:
Lightning protection is good on the outside of the house but static
discharge probably needs review.
Bob,
Take a look at the arrestors that Array Solutions sells, which are the
circuit that were built under the ICE name until the owner died a dec
Thanks Wes. I hesitated to un-stack the KPA500 off of the KAT500 and
disconnect all the cables. I suppose I need to look at my
configuration to reduce the likelihood of any damage to the PIN diodes
in the KPA500. Lightning protection is good on the outside of the
house but static disch
Unpowered, the input is connected to Ant 1. Each output has a 1 meg resistor to
ground, other than that just open relay contacts.
Wes N7WS.
On 9/17/2018 7:00 PM, Bob McGraw K4TAX wrote:
I didn't find the answer in the manual, so I'll ask here. I do see in the
manual where bleed resistors
I didn't find the answer in the manual, so I'll ask here. I do see in
the manual where bleed resistors are applied to the unused antenna
terminals to bleed off static charges. {page 15, Antenna
Selector. etc}
My question, do the relays in the tuner take the center conductor of all
4 matches
Mail list logo