Re: [Elecraft] KPA500 Voltage Test Problem

2012-02-12 Thread Timothy Eklin
I got it. I'm at 76 Volt on the HV now. It appears that I did not have one of the ribbon cables aligned properly. On Sun, Feb 12, 2012 at 12:22 PM, Timothy Eklin wrote: > I just assembled my KPA500. I'm using it on 240 VAC line and have the > fuse configured for this set up. The "Yellow" wir

[Elecraft] KPA500 Voltage Test Problem

2012-02-12 Thread Timothy Eklin
I just assembled my KPA500. I'm using it on 240 VAC line and have the fuse configured for this set up. The "Yellow" wire in on the TAP and when I did the initial test, I'm showing 16.8 Volts on the HV meter which is along way from 65 to 85 Volts as expected. Ideas as to what's wrong? 73 W8JJ __