A KX3 owner reported that on power-up, his KXAT3 internal ATU was being placed 
in bypass mode even when it had been in AUTO. I just confirmed this behavior 
and have correct it. The problem may exist in the latest beta release (1.57).

If you have have seen this symptom and can test the fix this evening, please 
email me directly. Let me know which revision of KX3 firmware you're presently 
using (use the FW REVS menu entry).

73,
Wayne