[Elecraft] Second Rx Filters

2009-02-01 Thread Julius Fazekas
In preparation for installing the second Rx, I will have a wider selection of filters for the main Rx versus the second Rx. Should the same filters be placed in their corresponding slots on both? In my main, I'll have the 2.7, 1.0, 500, 400 and 250. The second will have the 2.7 and 400 only at t

Re: [Elecraft] Second Rx Filters

2009-02-01 Thread Don Wilhelm
Julius, There is no one 'right way' - My opinion -- If you ever toggle the filters with the XFIL button, then having the filters in corresponding slots will be easier to remember - i.e, FL4 is the 400 Hz filter no matter whether the main or the sub. If you only use the DSP controls (width and

Re: [Elecraft] Second Rx Filters

2009-02-01 Thread Dick Dievendorff
ust works before you reconfigure filters after an EE INIT. Dick, K6KR -Original Message- From: elecraft-boun...@mailman.qth.net [mailto:elecraft-boun...@mailman.qth.net] On Behalf Of Julius Fazekas Sent: Sunday, February 01, 2009 6:14 AM To: elecraft@mailman.qth.net Subject: [Elecraft] S