[K3] [Elecraft] [k3] Wattmeter calibration

2008-06-27 Thread Dave G4AON
I calibrated my K3 power meter against a calibrated (bought assembled & calibrated) LP100 that is only a few months old. My WMTR HP calibration is 062. You mentioned the Acom 1000, I also have one of those. On mine (and it was mentioned in one of the reviews as well), the digital power level

Re: [K3] [Elecraft] [k3] Wattmeter calibration

2008-06-27 Thread G4ILO
GW0ETF wrote: > > Finally I got round to checking the wattmeter calibration as I've felt > it's been giving out power levels below what the wattmeter on the front > panel reports ever since I've had it. > > First alerted when my Acom 1000 seemed to giving low output until I saw > the amp's inpu

[K3] [Elecraft] [k3] Wattmeter calibration

2008-06-27 Thread GW0ETF
Finally I got round to checking the wattmeter calibration as I've felt it's been giving out power levels below what the wattmeter on the front panel reports ever since I've had it. First alerted when my Acom 1000 seemed to giving low output until I saw the amp's input reporting a significantly lo