Rolf, You will have to somehow get J4 and J5 perpendicular to the board. Forcing them into alignment with the screws will likely break something.
I have not had any past problems in accomplishing that feat. Be certain C60 and C45 are the proper values of 0.001 uf (marked 102) - the .001 monolythic capacitors are not as thick as the .01 uf and .047 uf capacitors. The .001 uf caps do fit snug against the U1 socket. 73, Don W3FPR > -----Original Message----- > > I encountered a problem when building KAT2. I'm in page 7 in revision D > manual. > > The fifth step says: > > "Install the two 16-pin female connectors, J4 and J5, on > the top of > the Control board... Make sure the connectors are > perpendicular to the board" > > To put in words J4 cannot be installed perpendicular to the board. C60 > and C45 are so thick. They both are installed very near to U1 socket. I > cannot move them any closer to U1. The angle between J4 and J5 is > several degrees when looking connectors from end view. I don't know is > it safe to go on and let the 4-40 screws to solve the problem by > cracking J4, C60 or C45. > > Rolf Moberg > > _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com