The IEC61000-4-11 Standard tests the Hold-up time of the power supply.
The IEC61000-4-14 Standard (I believe) introduces a disturbance into
the AC mains.
--
From: plaw...@west.net
To: emc-p...@majordomo.ieee.org
Subject: IEC61000-4-11 versus IEC61000-4-14
List-Post:
Hello all,
I need to know if we have to get FCC Type Approval before shipping cellular
phones into the following countries: Dominican Republic, Mexico, Peru, and
Columbia. Any help or suggestions would greatly be appreciated.
Thanks,
Barbara
-
This message is coming from the emc-pstc
What are the Peruvian and Dominican Republic transmitter type acceptance
regulatory requirements? Do they rely on the FCC ID number? If a cell phone
does not yet have an FCC ID number, is there an Peruvian or Dominican ID number
that is required?
I am experiencing some delays with the Type
What is the difference between the IEC61000-4-11 and -14 standards? Is one
more stringent than the other?
The descriptions from the IEC web page sound similar:
---
IEC 61000-4-11 (1994-06)
Electromagnetic compatibility (EMC) - Part 4: Testing and measuring techniques
- Section 11: Voltage
--
From: rehel...@mmm.com
To: emc-p...@majordomo.ieee.org
Subject: IEC 61000-4-14
List-Post: emc-pstc@listserv.ieee.org
Date: Thursday, April 08, 1999 12:07PM
I recently have heard about 3 new standards, IEC61000-4-13, (Harmonics
Interharmonics) IEC61000-4-14 , (Voltage Fluctuations),
Hi Folks
The following UK organisation runs 1-2 day courses on IEC 61508 and related
PES, and issues a number of guides
ERA Technology Ltd
Cleeve Rd
Leatherhead
Surrey KT22 7SA
England
Tel + 44-1372-367027
Fax: +44-1372-377927
email: conferen...@era.co.uk
Contact: Laura Viscione
Main URL:
We are looking for furniture (especially chairs tables) that are designed
for use in a ESD sensitive environment.
Can anyone give us info of manufacturers ?
Thanks,
Hans Vigne
TA Q Eng
OPTION INTERNATIONAL
Vaartkom 31 bus 8
B-3000 Leuven BELGIUM
Tel : +32 16 317 480
Fax : +32 16 20 71 64
Dear Jim,
Bruel and Kjaer http://www.bk.dk/; has over the years published a lot of
articles
on these kind of tests. In many cases they wrote or drove the test method
and/or
the standard. You can enquire of them what technical articles they have on
test
methods. They have offices around the world
Hello all,
Eric's comments below triggered an one thing I forgot to mention in my
earlier mail.
A slight correction to comments/clarification offered by Eric Lifsey:
The Australian EMC Framework (legislation/regulation) does not cover a
product which is has not been sold in Australia. If an
A recognised lab is required for Telecommunications (A-Tick) EMC testing,
but not usually for the C-Tick.
Barry Esmore
AUS-TICK (Australian Approval Consultants)
Phone: + 61 3 9886 1345
Fax:+ 61 3 9884 7272
Email: bar...@melbpc.org.au
--
From: rehel...@mmm.com
To: Barry Esmore
Harry:
Check out westbay emc software. We use it. for a description and free
downloads see:
http://www.tempest-inc.com/software.htm
Lou
At 10:51 AM 4/8/99 -0700, you wrote:
Where can I get ferrite bead SPICE models in the 1Mhz to 100Mhz range. I
desire something simple that can
Richard,
I am not with the SMA (actually, it is now the ACA - Australian
Communications Authority - responsible for telecoms, EMC radcom licensing
etc) but I may be able to help a little. I own and run a consulting
business specializing in regulatory requirements in Australia and NZ. I
have
Richard et al,
I believe what Richard really needs to know is the cost of arranging to be
represented by someone in Australia. The regulatory aspect is certainly a
bargain (by not being charged for registering with the ACA) but contracted
representation is usually a recurring cost. Perhaps an
13 matches