RE: NEBS operating temperature cycle criteria GR-63

2008-05-27 Thread JIM WIESE
Hello Chris, The answer is +55C, as later versions of GR-63 define shelves as 36” in height or less. Shelves are tested to +55C short term. But that is not the total solution to your problem, the GR-63 you are referencing is several revisions obsolete. You will need GR-63-CORE Issue 3, Ma

NEBS operating temperature cycle criteria GR-63

2008-05-27 Thread Chris
Folks I have a question regarding NEBS operating temperature duration for our NEBS experts. Operating and humidity criteria R4-7 GR-63 issue 1, October 1995. 1. shows 50C @ 32%RH dwell for 12 hours and 2. 50C @ 15%RH dwell for 4hrs * 55C for equipment shelves that fill less than

VCCI logo in dxf format

2008-05-27 Thread Kbalasubramanian
Dear Members, We are trying to emboss the VCCI logo in the plastic casing of an ITE product and we need VCCI logo in dxf format. From the VCCI official website we are able to get the eps & jpg format only but we are not able to create the logos properly with these files. May I request the fo

Re: VCCI logo in dxf format

2008-05-27 Thread Scott B. Lacey
The eps is in vector format, the jpg is in rastor format. If you do not receive the logo in dxf format >from a list member, go to www.google.com and type "eps to dxf" in the search bar. There are several freeware converters available. Scott B. Lacey On 27 May 2008 at 19:40, kbalasubraman.