Re: [PSES] Standard for water hoses

2012-10-22 Thread Brian Oconnell
PSEN Vol3 No4, Dec 2007 Check PAGs and CTL notices. And your corporate name-sake should have some internal docs on this construction. Brian -Original Message- From: emc-p...@ieee.org [mailto:emc-p...@ieee.org]On Behalf Of IBM Ken Sent: Monday, October 22, 2012 12:32 PM To: EMC-PSTC@LISTS

[PSES] Standard for water hoses

2012-10-22 Thread IBM Ken
Hello! Are there any standards (I'm interested in Product Safety Standards from UL, CSA, the IEC, or EN standards) covering water-carrying hoses? I am looking for something that covers flammability, construction, pressure rating, etc. The end product is a piece of ITE certified to 60950-1, if th

Re: [PSES] Enamel layer of windings in primary of mains transformer or AC motor

2012-10-22 Thread McInturff, Gary
I believe that is correct Gary From: Ted Eckert [mailto:ted.eck...@microsoft.com] Sent: Monday, October 22, 2012 10:13 AM To: EMC-PSTC@LISTSERV.IEEE.ORG Subject: Re: [PSES] Enamel layer of windings in primary of mains transformer or AC motor Hello Scott, Others will correct me if I am wrong, b

Re: [PSES] Enamel layer of windings in primary of mains transformer or AC motor

2012-10-22 Thread Ralph . McDiarmid
I think it's too easily nicked and likely too thin to be relied upon for Basic Insulation, with the dielectric requirement which comes with that classification. ___ Ralph McDiarmid | Schneider Electric | Solar Bu

Re: [PSES] Enamel layer of windings in primary of mains transformer or AC motor

2012-10-22 Thread Brian Oconnell
Assesment standard not specified. answer = No -> per UL508 and/or UL60950-1, film-coated wire is considered to be an uninsulated live part. Can be considered 'Functional' insulation only where the particular standard or building code allows that construction, and the term has been defined. Brian

Re: [PSES] Recast of RTTE directive

2012-10-22 Thread Elliott Mac-FME001
Thanks, Lauren. Does anyone know what the proposed Interoperability requirements being proposed are? Best regards, Mac Elliott [] General Public From: Crane, Lauren [mailto:lauren.cr...@kla-tencor.com] Sent: Monday, October 22, 2012 1:35 PM To: EMC-PSTC@LISTSERV.IEEE.ORG Subject: [PSES] R

[PSES] Recast of RTTE directive

2012-10-22 Thread Crane, Lauren
The EU Commission has published a proposal for the recast of the RTTE Directive, in part intended to bring it in line with the New Legislative Framework. Press release http://europa.eu/rapid/press-release_IP-12-1109_en.htm Regards, Lauren Crane KLA-Tencor - -

Re: [PSES] Enamel layer of windings in primary of mains transformer or AC motor

2012-10-22 Thread Ted Eckert
Hello Scott, Others will correct me if I am wrong, but I believe that the enamel on windings is considered functional insulation only. Regards, Ted Eckert Compliance Engineer Microsoft Corporation ted.eck...@microsoft.com The opinions expressed are my own and do

[PSES] Enamel layer of windings in primary of mains transformer or AC motor

2012-10-22 Thread Scott Xe
> Is the enamel layer of windings of mains transformer or motor considered as a > basic insulation? Lots of people point out that the primary windings or motor > windings are live part and requires double or reinforced insulation if the > user accessible object could be touch the windings. If the