Re: [PSES] new EMC Directive

2013-05-10 Thread Charlie Blackham
The changes are only (meant to be) an alignment of the EMCD with the NLF (New Legislative Framework) Decision 768/2008/EC. Requirements on manufacturers haven't really changed, but additional requirements are placed on those in the supply chain, set out in section 3.2 3.2. Obligations of

Re: [PSES] new EMC Directive

2013-05-10 Thread Willem Jan Jong
Dear experts, I have also visited the Dublin meeting, the publication will be later than expected. Indeed Mrs. Papiewska of the EU Commission explained the legal adoption is scheduled for October 2013. After that some time is needed to perform all editorial and administrative actions. So

Re: [PSES] Mode-stirred, Mode-tuned, Reverb - what's the difference?

2013-05-10 Thread Luke Turnbull
I've seen this on a video related to Frank Leferink's reverb tents, where the modes are stirred by shaking the side wall of the tent. The fabric is think enough to see the tube inside. Luke Turnbull From: emc-p...@ieee.org [mailto:emc-p...@ieee.org] On Behalf Of Ken Javor Sent: 09 May 2013

Re: [PSES] new EMC Directive

2013-05-10 Thread Kunde, Brian
Charlie, Thanks for this information. It was most helpful. But, like always, I have a question. If I buy a Dell computer in the USA and ship it to Europe to sell as part of a system including hardware produce by our company, do I have to put our company's name and address on the Dell computer

Re: [PSES] Flicker help

2013-05-10 Thread John Woodgate
In message j10vnrlsz9irf...@jmwa.demon.co.uk, dated Thu, 9 May 2013, John Woodgate j...@jmwa.demon.co.uk writes: Second, the last note in A.14 says that Pst and Plt are to be determined analytically.  As I have done the calculations don?t seem to be very different from the measured values (as

[PSES] safety 60950 and surge suppression circuits

2013-05-10 Thread Bill Owsley
I'm running into a dilemma.   Not being a Safety Engineer myself, but rubbing elbows with them... On a piece of ITE equipment, I need some surge suppression for worldwide markets with one annoying requirement for 4 kV, otherwise just 2 kV line to earth, and using either plugable cords or

Re: [PSES] new EMC Directive

2013-05-10 Thread Knighten, Jim L
By the end of the transition period, all Product Declarations of Conformity must have been reissued showing compliance with this new Directive. Jim __ James L. Knighten, Ph.D. EMC Engineer Teradata Corporation 17095 Via Del Campo San Diego, CA 92127 858-485-2537 - phone

Re: [PSES] Mode-stirred, Mode-tuned, Reverb - what's the difference?

2013-05-10 Thread Brent DeWitt
Title: Re: [PSES] Mode-stirred, Mode-tuned, Reverb - what's the difference? The small chamber with the lights was the work of Mike Hatfield, then of NSWC Dahlgren.Brent DeWitt-Original Message- From: Luke Turnbull Sent: May 10, 2013 7:07 AM To: