Hi Brian,
Can you ask your IT people to disable network access on the XP computer?
It would no longer be a risk to the company. Data transfer would have to
be via diskette or USB thumbdrive.
I've worked at other facilities with specialized engineering computers 'off
the network'.
Pat
On Dec 20
I recommend that you discuss these issues with Mathieu direct. FYI, he
is one of those who is continually commuting around the world, so you
might have to wait a few days for a reply.
John Woodgate OOO-Own Opinions Only
J M Woodgate and Associates www.woodjohn.uk
Rayleigh, Essex UK
On 2017-12-
All,
I'm looking for an AC+DC power supply that can perform Boeing's Abnormal DC
Content test for the 787. It requires +/- 55 VDC on top of the three phase 120
Vac power. We're replacing an Elgar unit which has worked well for years. I'm
looking to avoid Ametek, but they've swallowed Elgar, So
Kevin,
Thanks for yr information!
Regards,
Scott
On 21 Dec 2017 12:50 am, "Kevin Robinson" wrote:
> Specifications can be found here https://www.atecorp.com/
> products/biddle/577500-57j. Manufacturer ratings 3 phase at 20A, single
> phase at 40 A
>
> Lots of places used to rent, where I use
Sorry, I forgot about the attachments. I think the best way to go is for
anyone who wants them to ask Mathieu by email.
John Woodgate OOO-Own Opinions Only
J M Woodgate and Associates www.woodjohn.uk
Rayleigh, Essex UK
On 2017-12-21 16:08, John Woodgate wrote:
I asked Mathieu van den Bergh of
I asked Mathieu van den Bergh of CNS, who knows about this in depth.
Here is his response, which I have permission to quote.
QUOTE
/Ametek Cal. Inst. offers software that runs under Windows-7 //*(both 32
and 64 bit).*//So does Teseq (they sell the same system under the Teseq
brand. Note that
6 matches