Re: [PSES] ANSI 63.10 2020 Clause 7.6.3 Pulsed Emissions

2024-01-23 Thread Larry K. Stillings
Hi John, Ok thanks. I’m mixing power (Watts) vs. voltage and/or current. If I was dealing in units of Watts, then that is where the 10 * log would come into play because I’ve already “squared” Larry K. Stillings Compliance Worldwide, Inc. Test Locally, Sell Globally and Launch Your Products

Re: [PSES] ANSI 63.10 2020 Clause 7.6.3 Pulsed Emissions

2024-01-23 Thread John Woodgate
Microvolts/m requires 20*log( ), like anything based on voltage or current. Your example of a transmitter is based on power. On 2024-01-23 16:24, Larry K. Stillings wrote: Hello All, Maybe this is not the correct forum and I should put in an inquiry into the ANSI C63.10 committee directly,

[PSES] ANSI 63.10 2020 Clause 7.6.3 Pulsed Emissions

2024-01-23 Thread Larry K. Stillings
Hello All, Maybe this is not the correct forum and I should put in an inquiry into the ANSI C63.10 committee directly, however before I did that I wanted to get some help here. In the 2020 edition of the ANSI 63.10 standard they have added a calculation example page for pulsed emissions in

Re: [PSES] Test lab in Germany - LVD testing

2024-01-23 Thread Charlie Blackham
Amund Try Accredited Bodies - DAkkS - German Accreditation Body with Search term "62368" and Conformity Assessment Activity "Testing Laboratory" Best regards Charlie Charlie Blackham Sulis Consultants Ltd Tel: +44 (0)7946 624317 Web:

[PSES] Test lab in Germany - LVD testing

2024-01-23 Thread Amund Westin
On behalf of a local company, I’m looking for a German test lab within LVD testing (EN 62368-1). I have a listing of all CB scheme labs in Germany but would appreciate suggestions of other labs. Thanks! Best regards / Mit freundlichen Grüßen / Mvh Amund Westin