re: IEC1000-4-12

1998-09-02 Thread Harald Buchwald
Hi Roger, The EN 61000-4-12 is named e.g. in the EN 61800-3:1996: Product family standards for PLC. - Harry Buchwald EMC Division Manager ITE/ISM Products MIKES Product Service GmbH - Original Text From: , on 27.08.98 16:38: To:

re: Status of IEC601-1-2 ?

1997-07-31 Thread Harald Buchwald
Hi Pat, As a member of TC 62 WG13 I like to answer your question. >From the second edition of the draft IEC 601-1-2 we received more than 100 pages comments and objections. Meanwhile, during three meeting, all of this was discussed and will be included in the new version, which will be discuss

RE: ESD Simulators

1997-07-15 Thread Harald Buchwald
Hi all, We have three different guns here at MIKES Product Service. This are an old one from Haefely (very good because works up to 35kV !!!), the Mini-Zip from Keytec and 3 times the NSG435 from Schaffner. For handling and testing the most popular gun is the Schaffner in our lab ! If you have a

ISO 11452-5

1997-03-04 Thread Harald Buchwald
Hi all, Did somebody can give me information regarding ISO 11452-5. As far as I know this regulation talks about stripline! Any information is wellcome! Harald Buchwald, MIKES Product Service

Immobilizer approval

1997-02-18 Thread Harald Buchwald
Hallo, Does somebody havc information regarding approvals for car immobilizer (frequency 125kHz) very low power in the following countries: Thailand Argentina Mexiko Brasil Paraquay Saudi Arabia Equipt Any information would be helpfull Approval required ?, Contact adress, Contact partner, Standa

re: Korea Requirements

1997-01-09 Thread Harald Buchwald
Hi Bill, Happy New Year. We have checked the Korean Regulation. According to these regulation only Monitor, Printer and the adapter for a notebook PC require safety approval (similar as IEC950). But all ITE equipment needs EMI approval. From July 1997 the EMI standard for personal computer will be

re: Korean Regulatory

1996-12-19 Thread Harald Buchwald
SERVICE ASIA LTD, Att. Mr. Stefan Reis, 9/F.,Jung Gok Bldg., 44-25 Yoido-Dong, Yungdeungpo-Ku, Seoul, R.O.K., Tel: +82-2-783-9251, Fax: +82-2-783-9253 Have fun Harald Buchwald MIKES PRODUCT SERVICE GmbH, Germany - Original Text From: Tony Fredriksson , on 17.12.1996 15:45: To: "emc

CEMASTER

1996-12-17 Thread Harald Buchwald
. Harald Buchwald MIKES Product Service GmbH, Germany

Standards for patient-monitors

1996-12-17 Thread Harald Buchwald
Hi all, Inm locking for an information regarding patient monitor. The system will be installed or used in a helicopter. Are there any special EU-regulation for EMC or SAFETY ? Any information will be usefull Many thanks Harald Buchwald, MIKES Product Service GmbH, Germany

fwd: re: Car Adaptor need CE Mark?

1996-12-06 Thread Harald Buchwald
- Original Text From: Harald Buchwald@emv@stk, on 06.12.1996 09:51: To: @stk; Internet Gateway@Services@PSNBL[] Hi Mike, We got a statement from the KBA (Kraftfahrtbundesamt) - Notified Body according Automotive Directive that such equipment need to have a E-Mark according 95/54/EC