Halon resistant power cords.

2000-06-27 Thread Kelly Tsudama
Kelly Kelly Tsudama Cisco Systems ktsud...@cisco.com 408-527-0216 408-525-9150 fax 408-322-9024 pager --- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send ma

Re: Sizes for Power, Control and Signal Cords/Cables/Wires

2000-03-22 Thread Kelly Tsudama
emc-pstc > >For help, send mail to the list administrators: > Jim Bacher: jim_bac...@mail.monarch.com > Michael Garretson:pstc_ad...@garretson.org > >For policy questions, send mail to: > Richard Nute: ri...@ieee.org > ***

Re: standard for lead shot dielectric testing

2000-03-17 Thread Kelly Tsudama
ine: > unsubscribe emc-pstc > >For help, send mail to the list administrators: > Jim Bacher: jim_bac...@mail.monarch.com > Michael Garretson:pstc_ad...@garretson.org > >For policy questions, send mail to: > Richard Nute: ri...@ieee.org > ***

Re: Correction factor for power supply cords.

2000-03-10 Thread Kelly Tsudama
and testing for the safety of equipment. >If you are using a flexible cord in a high ambient I would contact the mfg for >the appropriate derating. > > > > >Kelly Tsudama on 03/09/2000 09:33:14 PM > >Please respond to Kelly Tsudama > >To: emc-p...@majordomo.ieee.

Correction factor for power supply cords.

2000-03-10 Thread Kelly Tsudama
Is there a need to "de-rate" a power cord's current rating based on the expected ambient temperature? If so, where in the NEC did I miss this fact? If not, why not? Thanks for your help, Kelly ******** Kelly Tsudama Cisc